Publications

STOCK M., BARAT P., PINOT P., BEAUDOUX F., ESPEL P., PIQUEMAL F., THOMAS M., ZIANE D., ABBOTT P., HADDAD D., KUBARYCH Z., PRATT J.R., SCHLAMMINGER S., FUJII K., FUJITA K., KURAMOTO N., MIZUSHIMA S., ZHANG L., DAVIDSON S., GREEN R.G., LIARD J., SANCHEZ C., WOOD B., BETTIN H., BORYS M., BUSCH I., HÄMPKE M., KRUMREY M. ET NICOLAUS A., “A comparison of future realizations of the kilogram”, Metrologia, 55, T1, 2018, DOI: 10.1088/1681-7575/aa9a7e.

 

VINCENT P., RODRIGUES D., LARSONNIER F., GUIANVARC'H C. ET DURAND S., "Acoustic transfer admittance of cylindrical cavities in infrasonic frequency range", Metrologia, Volume 56, Numéro 1, novembre 2018, DOI: 10.1088/1681-7575/aaee28.

 

BENTOUATI D., DURGUT Y., OTAL P., PLIMMER M., PRAŽÁK D., SABUGA W., EHLERS S. ET SINIR E., "Calibration methods for negative gauge pressure down to -100 kPa", Meas. Sci. Technol. 29 (2018) 035007, DOI: 10.1088/1361-6501/aa92ea.

 

FUJITA Y., ZUBLER T., MASTROPIERRO J., TRUJILLO S., CEKIEL I., MALTA D., LOREFICE S., BALLEREAU P., MEURY P.A., ZHANG Z., WOLF H., TROCHTA D., SAKARYA O., VAN ANDEL I., BUCHNER C., SPOHR I., FURTADO A., LUGADIRU B., MEKAWY M., JONKER D., KUMAR A. ET ANUAR Z., "CCM.V-K3: CCM Key Comparison of Viscosity", Metrologia, Volume 55, Technical Supplement, 2018, DOI: 10.1088/0026-1394/55/1a/07010.

 

MAURY R., STRZELECKI A., AUCLERCQ C., LEHOT Y., LOUBAT S., CHEVALIER J. ET BEN RAYANA F., "Cryogenic flow rate measurement with a laser Doppler velocimetry standard", Measurement Science and Technology, Volume 29, Number 3, 2018, DOI: 10.1088/1361-6501/aa9dd1.

 

BOINEAU F., HURET S., OTAL P. ET PLIMMER M., "Development and characterisation of a low pressure transfer standard in the range 1 Pa to 10 kPa", Acta IMEKO, vol. 7, no. 1, article 16, March 2018, DOI: 10.21014/acta_imeko.v7i1.496.

 

SARRAF C. ET DAMION J.-P., "Dynamic pressure sensitivity determination with Mach number method", Measurement Science and Technology, Volume 29, Numéro 5, 2018, DOI: 10.1088/1361-6501/aaa664.

 

KÖNEMANN J., SABUGA W., PRAŽÁK D., RABAULT T. ET WÜTHRICH C., " Final report on supplementary comparison EURAMET.M.P-S14 of hydraulic gauge pressure standards from 50 MPa to 1000 MPa ", Metrologia, Volume 55, Technical Supplement, 2018, DOI: 10.1088/0026-1394/55/1a/07008.

 

AVERLANT P. ET DUFLON C., "Metrological characterisation of the 5 kN.m torque standard machine of LNE", Journal of Physics: Conf. Series, 1065, 2018, DOI: 10.1088/1742-6596/1065/4/042044.

 

PINOT P. ET SILVESTRI Z., "Optical power meter using radiation pressure measurement", Measurement, 131, 2019, 109-119, DOI: 10.1016/j.measurement.2018.07.087.

 

OGHEARD F., MARGOT S. ET SAVARY J., "Recent improvements of the French liquid micro-flow reference facility", Measurement Science and Technology, Volume 29, Number 2, 2018, DOI: 10.1088%2F1361-6501%2Faa97ef.

 

VAN DER GRINTEN J., FOULON H., GUNNARSSON A., ET MICKAN B., "Reducing measurement uncertainties of high-pressure gas flow calibrations by using reference values based on multiple independent traceability chains", tm-Technisches Messen, 85(12), 754-763, DOI: 10.1515/teme-2018-0019.

 

DE HUU M., BÜKER O., CHRISTENSEN R., MACDONALD M., MAURY R., SCHRADE M., PETTER H.T. ET STADELMANN P., " The European Research Project on Metrology for Hydrogen Vehicles - MetroHyVe ", Journal of Physics: Conf. Series, 2018, DOI: 10.1088/1742-6596/1065/9/092017.

Communications

JUNCAR P. ET THOMAS M., "A self-calibrated frequency doubled nd:yag laser. Application to the French Kibble balance", CPEM 2018, Paris, 11 juillet 2018.

 

ZIANE D., THOMAS M. ET PINOT P., "Coil Velocities Error Reduction In The French Kibble Balance Experiment", CPEM 2018, Paris, 9 juillet 2018.

 

MAURY R. ET AL, "Cryogenic flow rate measurement with a Laser Doppler Velocimetry standard",  ISFFM, Mexique, Quérétaro, 21-23 mars 2018.

 

MAURY R., OUERDANI A., AUCLERCQ C., LEHOT Y., LOUBAT S., CHEVALIER J. ET BEN-RAYANA F., " Développement d’un dispositif primaire de débitmétrie du GNL par Vélocimétrie Laser Doppler ", 7th International Metrology Conference - CAFMET 2018, Maroc, Marrakech, 9-12 avril 2018.

 

KHELIFA N., " Effet de la mesure de la température du point de rosée sur une  raie d’absorption de la vapeur d'eau dans le proche infrarouge ", 7th International Metrology Conference - CAFMET 2018, Maroc, Marrakech, 9-12 avril 2018.

 

OTAL P., YARDIN C. ET FISCHER N., " Etalonnage des balances manométriques et modélisation des sections efficaces des ensembles piston-cylindre ", 7th International Metrology Conference - CAFMET 2018, Maroc, Marrakech, 9-12 avril 2018.

 

OGHEARD F., "First steps toward dynamic reference calibration methods for liquid flow meters at LNE-CETIAT", ISFFM, Mexique, Quérétaro, 21-23 mars 2018.

 

SILVESTRI Z., BOINEAU F., OTAL P. ET WALLERAND J., "Helium-Based Refractometry for Pressure Measurements in the Range 1-100 kPa", 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), Paris, 2018, DOI: 10.1109/CPEM.2018.8501259.

 

AVERLANT P. ET DUFLON C., "Metrological characterisation of the 5 kN.m torque standard machine of LNE", XXII IMEKO World Congress, Irlande, Belfast, 3-6 septembre 2018.

 

MAURY R. ET AL., "Numerical and Experimental Investigations on the Shape and Roughness of Cylindrical Critical Flow Venturi Nozzle (CFVN)", ISFFM, Mexique, Quérétaro, 21-23 mars 2018.

 

BARTOLI C., JURGEIT S., KLAUS L. ET LARSONNIER F., "Preliminary comparison on seismometer frequency response following ISO 16063-11 calibration by primary means", IOP Conf. Series: Journal of Physics: Conf. Series, 1065 (2018) 222018, DOI: 10.1088/1742-6596/1065/22/222018.

 

PINOT P. ET SILVESTRI Z., "Pyrolytic Carbon: Applications of Diamagnetic Levitation in Metrology", Conference on Precision Electromagnetic Measurements (CPEM 2018), France, Paris, 8-13 juillet 2018, DOI: 10.1109/CPEM.2018.8501041.

 

OGHEARD F. ET AL., " Validation d’un banc d’étalonnage primaire en microdébitmétrie liquide ", DeviceMed, https://www.devicemed.fr/dossiers/sous-traitance-et-services/metrologie_controle-sous-traitance-et-services/validation-dun-banc-detalonnage-primaire-en-microdebitmetrie-liquide/17027.

 

Publications

AVISON J., HARRIS P., ROBINSON S., RODRIGUES D., GUGLIELMONE C., HOF C., SADIKOGLU E. et CHUSHKOV M., "Final report: key comparison EURAMET.AUV.A-K5. 2019", Metrologia, 56, 1A. DOI: 10.1088/0026-1394/56/1A/09001

JULIEN L., NEZ F., THOMAS M., ESPEL P., ZIANE D., PINOT P., PIQUEMAL F., CLADE P., GUELLATI-KHELIFA S., DJORDJEVIC S., POIRIER W., SCHOPFER F., THEVENOT O., PITRE L. et SADLI M., « Le nouveau Système international d’unités – Le kilogramme, l’ampère, la mole et le kelvin redéfinis », Reflets de la physique, 62, juin 2019, 11-31, DOI: 10.1051/refdp/201962011

KUMME R., AVERLANT P., BARTEL T., GERMAK A. et KNOTT A., "Final report on the force key comparison CCM.F-K3 : 500 kN", Metrologia, 56, 1A, technical supplement 2019 DOI: 10.1088/0026-1394/56/1A/07001

OTAL P. et YARDIN C., "Modelling methods for pressure balance calibration", Measurement Science and Technology, 31, 27 décembre 2019, 3, DOI: 10.1088/1361-6501/ab5910

RODRIGUES D., ROSENKRANZ P., BARRERA-FIGUEROA S., GUGLIELMONE C. ,SOARES Z.M.D. et KLING C., "Supplementary comparison EURAMET.AUV.A-S2, 2020", Metrologia, 57, 1A, technical supplement ; 09001 DOI:10.1088/0026-1394/57/1A/09001

THOMAS M., "Kilogram and new SI definitions", High Temperatures - High Pressures, 48, 2019, 3,193-205.

THOMAS M., ESPEL P., ZIANE D., PINOT P. et F. PIQUEMAL, « La redéfinition du kilogramme et la balance de Kibble », Les reflets de la mesure, 62, 2019, 18-21

VINCENT P., LARSONNIER F., RODRIGUES D. et DURAND S., "Analytical modelling and characterisation of an infrasound generator in the air", Applied Acoustics, 148, mai 2019, 476-483, DOI:10.1016/j.apacoust.2018.12.033

Communications

PIQUEMAL F, « Evolution du SI le 20 mai 2019 », Université de Strasbourg, Société Française de Physique, Alsace, 30 janvier 2019.

F. BEAUDOUX, P. ESPEL, P. PINOT, F. PIQUEMAL, M. THOMAS, D. ZIANE, “Kilogram dissemination at LNE”, Metrology symposium, Radwag, Pologne, 7 mars 2019.

THOMAS M., « Le kilogramme : de l’artefact à la constante de Planck », ESPCI, 20 mai 2019.

BEAUDOUX F., ESPEL P., PINOT P., PIQUEMAL F., THOMAS M. et ZIANE D., “New from LNE Kibble balance”, CCM-WGR-kg, 14 mai 2019.

THOMAS M. et PIQUEMAL F., « Table ronde sur le SI » LNE Paris, France, 20 mai 2019.

MACDONALD M., DE HUU M., MAURY R. et BÜKER O, "Calibration of Hydrogen Coriolis Flow Meters Using Nitrogen and Air and Investigation of the Influence of Temperature on Measurement Accuracy", 18th International Flow Measurement Conference (Flomeko2019), 26-28 juin 2019.

GERSL J., BUSCHE P., DE HUU M., PACHINGER D., MÜLLER H., HÖLPER K., BERTASIENE A., VILBASTE M., CARE I., KAYKISIZLI H., MAAR L. et HAACK S., "Comparison of calibrations of wind speed meters with a large blockage effect", 18th International Flow Measurement Conference (Flomeko2019), Lisbonne, Portugal, 26-28 juin 2019.

OGHEARD F. et CASSETTE Ph., "Development of an optical measurement method for "sampled" micro-volumes and nano-flow rates", 18th International Flow Measurement Conference (Flomeko2019), Lisbonne, Portugal, 26-28 juin 2019

MAURY R., AUCLERCQ C., SCHRADE M. et PETTER H.T., "Hydrogen refuelling station calibration with a traceable gravimetric standard", 18th International Flow Measurement Conference (Flomeko2019), Lisbonne, Portugal, 26-28 juin 2019

SLUSE J. et MAURY R., "Influence of disturbing part on measurement of LDV package system", 18th International Flow Measurement Conference (Flomeko2019), Lisbonne, Portugal, 26-28 juin 2019

CARE I. et FOURNEAUX F., "Investigation of in-line pressure effect on Pitot tube measurements", 18th International Flow Measurement Conference (Flomeko2019), Lisbonne, Portugal, 26-28 juin 2019

LAMBERT M.A., MAURY R., VALIERE J.-C., FOUCAULT E., LEHNASCH G., MICKAN B. et VON LAVANTE E., "Numerical and Experimental Investigations on Cylindrical Critical Flow Venturi Nozzle (CFVN)", 18th International Flow Measurement Conference (Flomeko2019), Lisbonne, Portugal, 26-28 juin 2019

BEAUDOUX F., ESPEL P., PINOT P., PIQUEMAL F., THOMAS M. et ZIANE D., "Progress on the French LNE Kibble balance: towards the realization of the mass unit in France", QPM, Cracovie, 17-19 juin 2019

PIQUEMAL F., « Evolution du SI le 20 mai 2019 », Université de Pau, 24 septembre 2019

MAURY R. et al., “Cryogenic flow rate measurement with a laser”, 19th International Metrology Congress (CIM), Paris, France, 24-26 septembre 2019.

 LAMBERT M.A., MAURY R., VALIERE J.-C., FOUCAULT E. et LEHNASCH G., "Experimental and numerical investigations on the shape and roughness of cylindrical critical flow venturi nozzles", 19th International Metrology Congress (CIM), Paris, France, , DOI: 10.1051/metrology/201917003, 24-26 septembre 2019

OGHEARD F., "Development of a dynamic gravimetric calibration method for liquid water flow metering", 19th International Metrology Congress (CIM), Paris, France, DOI: 10.1051/metrology/201917001, 24-26 septembre 2019

BENTOUATI D., OTAL P. et PLIMMER M., "Development of calibration methods for differential pressure measurements with line pressures up to 10 MPa", 19th International Metrology Congress (CIM), Paris, France, 24-26 septembre 2019.

BATISTA E., FURTADO A., PEREIRA J., FERREIRA M., BISSIG H., GRAHAM E., NIEMANN A., TIMMERMAN A., OGHEARD F. et ALVES E SOUSA J., "New EMPIR project - Metrology for Drug Delivery", 19th International Metrology Congress (CIM), Paris, France, DOI: 10.1051/metrology/201915004, 24-26 septembre 2019

BEAUDOUX F., ESPEL P., PINOT P., PIQUEMAL F., THOMAS M.et ZIANE D., «News from LNE Kibble balance »,  Kibble balance technical meeting, Teddington, United Kingdom, octobre 2019.

BOUDAOUD A.W., OGHEARD F., LOPEZ-LEON T. et MCGRAW J.D., "Development of a Primary Portable System for the Measurement of Nano-flow Rates of Liquids", IFP MICROFLUIDICS 2019, Rueil Malmaison, France,  13-15 novembre 2019

 

Publications

BRIZARD M., MEGHARFI M. et VERDIER C., “Absolute falling-ball viscometer: evaluation of measurement uncertainty”, Metrologia, 42, 2005, 298-303.

CALCATELLI A., ARRHEN F., BERGOGLIO M., GREENWOOD J., KANGI R., JOUSTEN K., LEGRAS J.-C., RANTANEN M., VERBEEK J., MATILLA VICENTE C. et SZAULICH D., “Results of the regional key comparison EUROMET.M.P-K1.a in the pressure range from 0.1 Pa to 1000 Pa”, Metrologia, 42, 2005, Tech. Suppl., 07004.

DOPHEIDE D., MICKAN B., KRAMER R., HOTZE H.-J., VAN DER BEEK M., BLOM G., VALLET J.-P. et GORIEU O., “Final report on the CIPM Key Comparisons for Natural Gas at High-Pressure Conducted in November/December 2004 CCM.FF-5.a”, Metrologia, 43, 2006, Tech. Suppl., 07001.

DOPHEIDE D., MICKAN B., KRAMER R., VAN DER BECK M., BLOOM G.J. et VALLET J.-P., “The harmonized European gas cubic meter for natural gas as realized by PTB, NMi-VSL and LNE-LADG and its benefit for user and metrology”, Revue française de métrologie, 2, Vol. 2005-2, 35-42.

GOSSET A. et MADEC T., “Final Report: CCM.M-K3 comparison/50 kg mass”, Metrologia, 42, Tech. Suppl. 07003, 2005.

HAIDAR Y., TOLLENS E., SILVESTRI Z., DE FORNEL F., ZERROUKI C., PICARD A. et PINOT P., “Study and comparison of two polishing methods for platinum–iridium surfaces, by means of three characterization techniques”, Metrologia, 42, 2005, 115–128.

JOUSTEN K., BERGOGLIO M., CALCATELLI A., DUROCHER J.N., GREENWOOD J., KANGI R., LEGRAS J.-C., MATILLA C. et SETINA J., “Final report on the regional key comparison Euromet.M.P-K1.b (Euromet Project 442, Phase B) in the pressure range from 3·10-4 Pa to 0.9 Pa”, Metrologia, 42, Tech. Suppl. 07001, 2005.

MOLINAR G, BERGOGLIO M, SABUGA W, OTAL P, AYYILDIZ G, VERBEEK J et FARAR P, “Calculation of effective area A0 for six piston–cylinder assemblies of pressure balances. Results of the EUROMET Project 740”, Metrologia, 42, 2005, S197–S201.

OTAL P. et LEGRAS J.-C., “Metrological characterization of a new standard, in absolute and gauge pressure modes, in the range 1 Pa to 15 000 Pa”, Metrologia, 42, 2005, S216–S219

RABAULT T. et LEGRAS J.-C., “Calculation of the pressure distortion coefficient and uncertainty budget of the BNM/LNE 200 MPa national standard”, Metrologia, 42, 2005, S246–S249.

SABUGA W., BERGOGLIO M., RABAULT T., WALLER B., TORRES J.C., OLSON D.A., AGARWAL A., KOBATA T. et BANDYOPADHYAY A.K., “Final Report on Key Comparison CCM.P-K7 in the range 10 MPa to 100 MPa of hydraulic gauge pressure”, Metrologia, 42, 2005, Tech. Suppl. 07005.

SABUGA W., MOLINAR G., BUONANNO G., ESWARD T., RABAULT T. et YAGMUR L., “Calculation of the distortion coefficient and associated uncertainty of PTB and LNE 1 GPa pressure balances using finite element analysis—EUROMET project 463”, Metrologia, 42, 2005, S202–S206.

Communications

BEDIAT N., ARATEM Synthèse thématique « Faibles débits », janvier 2006.

AVERLANT Ph., “Calibration of strain cylinders used for the verification of compression testing machines”, 19th international conference on force, mass and torque (IMEKO TC3), Le Caire, Egypte, 19-23 février 2005.

KHELIFA N., LECOLLINET M. et HIMBERT M., “Molar Mass of Dry Air in Mass Metrology”, 19th international conference on force, mass and torque (IMEKO TC3), Le Caire, Egypte, 19-23 février 2005.

PINOT P., « Stabilité des étalons de masse et comportement superficiel : caractérisation de surface de matériaux utilisés pour la réalisation de kilogrammes de référence », Journée des métrologues du LNE, 5 avril 2005, Paris, France.

CALCATELLI P.A., ARRHEN F., BERGOGLIO M., GREENWOOD J., KANGI R., JOUSTEN K., LEGRAS J.C., RANTANEN M., VERBEEK J., VICENTE C.M. et SZAULICH D., “Results of the key comparison EUROMET.M.PK1. a (Euromet project 442 A) in the pressure range: 0.1 – 1000 Pa”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

JOUSTEN K., BERGOGLIO M., CALCATELLI A., DUROCHER J.N., GREENWOOD J., KANGI R., LEGRAS J.-C., MATILLA C. et SETINA J., “Results of the regional key comparison Euromet.M.P-K1.b in the pressure range from 3·10-4 Pa to 0.9 Pa”, The 4th CCM international conference on pressure metrology, Londres, Royaume-Uni, 20 avril 2005.

LEGRAS J.-C., “Link of regional and CIPM key comparisons: method and results in the high pressure range”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

LEGRAS J.-C. et OTAL P., “Stability and thermal transpiration effect: performances of the capacitance diaphragm gauges as transfer standards”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

MOLINAR G., BERGOGLIO M., SABUGA W., OTAL P., AYYILDIZ G., VERBEEK J. et FARAR P., “Calculation of effective area A0 for six piston-cylinder assemblies of pressure balances. Results of the EUROMET Project 740”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

OTAL P.et LEGRAS J.-C., “Metrological characterisation of a new standard, in absolute and gauge pressure mode, in the range 1 to 15000 Pa”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

RABAULT T. et LEGRAS J.-C., “Calculation of the pressure distortion coefficient of the BNM/LNE 200 MPa and the 1 GPa national standards”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

OLIVEIRA A.B.S et DAMION J.-P., “Modelling estimate of the associated uncertainty for dynamic calibration of pressure transducers”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

SABUGA W., MOLINAR G., BUONANNO G., ESWARD T., RABAULT T. et YAGMUR L., “Calculation of the distortion coefficient and associated uncertainty of PTB and BNM-LNE 1 GPa pressure balances using finite element analysis – EUROMET Project 463”, 4th CCM international conference on pressure metrology – High Vacuum to Very High Pressures, Londres, Royaume-Uni, 20 avril 2005.

BEDIAT N., « La métrologie des débits de liquide inférieurs à 1 litre par heure », 12e Congrès international de métrologie, Lyon, France, 20-23 juin 2005.

BRIZARD M., MEGHARFI M., MAHE E. et VERDIER C., « Développement d'un viscosimètre à chute de bille pour la mesure de la viscosité des fluides », 12e Congrès international de métrologie, Lyon, France, 20-23 juin 2005.

KHELIFA N., LECOLLINET M. et HIMBERT M., « Masse molaire de l’Air Standard : Quelle valeur pour la concentration d’argon », 12e Congrès international de métrologie, Lyon, France, 20-23 juin 2005.

MEURY P.A., MOLINS R., GOSSET A., « Définition d’un nouvel alliage métallique pour la réalisation d’étalons de masse secondaires », 12e Congrès international de métrologie, Lyon, France, 20-23 juin 2005.

OLIVEIRA A.B.S et DAMION J.-P., « Détermination de l’incertitude de la fonction de transfert d’un capteur de pression en basse fréquence », 12e Congrès international de métrologie, Lyon, France, 20-23 juin 2005.

OTAL P., LEGRAS J.-C., « Utilisation d’un nouvel étalon pour les étalonnages en pression absolue et relative dans le domaine de 1 à 15 000 Pa », 12e Congrès international de métrologie, 20-23 juin 2005, Lyon, France.

SANCHEZ J.R., MÜLLER H., CARE I., CORDIER-DUPERRAY Y. et SEYNHAEVE J.M., « Intercomparaison d’étalonnage d’anémomètres par comparaison à un anémomètre Doppler Laser », 12e Congrès international de métrologie, Lyon, France, 20-23 juin 2005.

KHÉLIFA N., “Air Moisture Measurement: The Indiscreetness of the Dew-point Hygrometer”, 19th Metrology Symposium, Opatija, Croatie, septembre 2005.

VALLET J.-P., “The harmonized European method for measuring natural gas cubic meter”, Congrès international du gaz de l’A.F.G., Paris, France, septembre 2005.

OLIVEIRA A.B.S et DAMION J.-P., “Determination of uncertainty of a reference pressure transducer transfer function in frequency bellow 100 Hz”, COBEM 2005, International Congress of Mechanical Engineering, Ouro Preto, Minas Gerais, Brésil, 2005.

Publications

BECERRA L.O., BERRY J., CHANG C.S., CHAPMAN G.D., CHUNG J.W., DAVIS R.S., FIELD I., FUCHS P., JACOBSSON U., LEE S.M., LOAYZA V.M., MADEC T., MATILLA C., OOIWA A., SCHOLZ F., SUTTON C. et VAN ANDEL I., “Magnetic properties comparison of mass standards among seventeen national metrology institutes”, Metrologia, 43, 2006, 426-434.

DOPHEIDE D., MICKAN B., KRAMER R., HOTZE H.-J., VAN DER BEEK M., BLOM G., VALLET J.-P. et GORIEU O., “Final report on the CIPM key comparisons for natural gas at high-pressure conducted in November/December 2004 CCM.FF-5.a”, Rapport du CCM, CCM.FF-5.a-Final Report, 2006.

DOPHEIDE D., MICKAN B., KRAMER R., HOTZE H-J, VALLET J.-P., HARRIS M.R., JIUNN-HAUR SHAW et KYUNG-AM PARK, “Final report on the CIPM Key Comparisons for compressed air and Nitrogen conducted in November 2004/June 2005 CCM.FF‑5.b”, Rapport du CCM, CCM.FF-5.b-Final Report, 2006.

DOPHEIDE D., MICKAN B., KRAMER R., HOTZE H-J, VAN DER BEEK M., BLOM G., VALLET J.-P. et GORIEU O., “First approach towards a global reference value for natural gas flow measurement at high pressure”, Bulletin de l’OIML, XLVII, 2, 2007, 5-12.

GUIANVARC'H C., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., “Improved formulation of the acoustic Transfer admittance of cylindrical cavities”, Acta Acustica, 92, 2006, 345-354.

KHELIFA N., GUELLATI S., KERVIEL P. et LECOLLINET M., “Optical sensor for air moisture monitoring in mass metrology”, Phys. Chem. News, 28, 2006, 85-89.

SABUGA W., MOLINAR G., BUONANNO G., ESWARD T., LEGRAS J.-C. et YAGMUR L., “Finite element method used for calculation of the distortion coefficient and associated uncertainty of a PTB 1 GPa pressure balance - Euromet project 463”, Metrologia, 43, 2006, 311-325.

SUTOUR C., STUMPF C., KOSINSKI J.-P., SURGET A., HERVOUËT G., YARDIN C., MADEC T. et GOSSET A., « Détermination de la concentration en argon dans l’air ambiant pour le calcul de la masse volumique de l’air », Revue française de métrologie, 8, 2006, 311-325.

Communications

RODRIGUES D., GUIANVARC'H C., DUROCHER J.-N., BRUNEAU M., BRUNEAU A.-M. et LOTTON P., « Méthode de mesure d'impédance de petits éléments acoustiques », Congrès français d’acoustique, Tours, France, 24-27 avril 2006, 1029-1032.

MICKAN B., KRAMER R., DOPHEIDE D., HOTZE H.-J., HINZE H.-M., JOHNSON A., WRIGHT J., VALLET J.-P., “Comparison by PTB, NIST, and LNE-LADG in air and natural gas with critical venturi nozzles agree within 0.05 %”, 6th ISFFM, Queretaro, Mexique, 16-18 mai 2006.

VALLET J.-P., WINDENBERGER C., DOPHEIDE D., MICKAN B., VAN DER BEEK M. et BLOM G., “Traceability chain and uncertainty budget calculation for the French high pressure gas flow measurement laboratory LNE-LADG and the impact of the harmonization process with PTB-pigsar and NMI-VSL on this calculation”, 6th ISFFM, Queretaro, Mexique, 16-18 mai 2006.

MEURY P.A., “Surface reactivity of materials for the realization of mass standards”, Congrès EMCR 2006, Dourdan, France, 18-23 juin 2006.

BOINEAU F., LEGRAS J.-C. et OTAL P., “Calibration of Helium leaks: reference method and dissemination - Range from 4·10‑14 mole·s–1 (10–10 Pa·m3·s–1) to 4·10-6 mole·s–1 (10‑2 Pa·m3·s‑1)”, Spanish Vacuum Society, WS 18 Conference, Salamanca, Espagne, 26-28 juin 2006.

AVERLANT PH., “Transfert of the French accelerometry reference laboratory from CEA-CESTA to LNE”, XVIII IMEKO World Congress, Rio de Janeiro, Brésil, 17-22 septembre 2006.

Publications

AVERLANT PH., « Transfert du banc de référence en accélérométrie du CEA-CESTA au LNE », Revue française de métrologie, 10, 2007, 23-30.

KHÉLIFA N., LECOLLINET M. et HIMBERT M., “Molar mass of dry air in mass metrology”, Measurement, 40, 2007, 805-810.

MADEC T., MANN G., MEURY P.A. et RABAULT T., “Micro-mass standards to calibrate the sensitivity of mass comparators”, Metrologia, 44, 5, 2007, 266-274.

MADEC T., MEURY P.A., SUTOUR C., RABAULT T., ZERBIB S. et GOSSET A., “Determination of air density: a comparison of the CIPM thermodynamic formula and the gravimetric method”, Metrologia, 44, 6, 2007, 441-447.

MEURY P.A., HUNTZ A.M., MOLINS R., HERBST-GHYSEL M. et SEVERAC C., “Effect of the ambient atmosphere on the surface reactivity of materials for the realization of reference mass standards”, Metrologia, 44, 5, 2007, 253-265.

OTAL P., LEGRAS J.-C. et HAREL D., « Comparaison de la balance de pression absolue et du manomètre à colonne de mercure du LNE », Revue française de métrologie, à paraître.

RICHARD P., ULRICH J.-G., LAU P., BETTIN H., STEINDL D., PEUTO A., ARMITAGE D., DOWNES S., BAIRY G., MATILLA C., GOSSET A., BLICHFELD H., FILLINGER L., AKCADAG U. et ÇIFTÇI V., “Final report on the intercomparison EUROMET.M.D-K1 of volume standards by hydrostatic weighing (Euromet project 339)”, Metrologia, 44, Tech. Suppl., 2007, 07003.

RODRIGUES D., GUIANVARC’H C., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., “A method to measure and interpret input impedance of small acoustic components”, Journal of Sound and Vibration, à paraître.

SUTOUR C., STUMPF C., KOSINSKI J.-P., SURGET A., HERVOUËT G., YARDIN C., MADEC T. et GOSSET A., “Determination of the argon concentration in ambient dry air for the calculation of air density”, Metrologia, 44, 6, 2007, 448-452.

Communications

MEURY P.A., “Mass standard for the French watt balance experiment”, Watt balance technical meeting (WBTM 2007), BIPM, Sèvres, France, 15-16 février 2007.

MEURY P.A., “Progress on the French watt balance”, Euromet Mass 2007, NPL, Royaume-Uni, 28 février-2 mars 2007.

MEURY P.A., “Mass standard for the French watt balance experiment”, Euromet Mass 2007, NPL, Royaume-Uni, 28 février-2 mars 2007.

MEURY P.A., “News from LNE”, Euromet Mass 2007, NPL, Royaume-Uni, 28 février-2 mars 2007.

KHELIFA N., “Water vapour effects in mass measurement”, 6th International Conference on Measurement, Smolenice, Slovaquie, 20-24 mai 2007, article en ligne : arXiv:0705.0925.

BEDIAT N et DAMION J.-P., « Influence du comportement dynamique de sondes de température sur la détermination d'une puissance thermique en régime transitoire », 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

BEDIAT N., DOIHARA R., SHIMADA T., TERAO Y. et TAKAMOTO M., « Utilisation d'un diviseur rotatif à aile double pour l'étalonnage en débitmétrie liquide », 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

DOPHEIDE D., MICKAN B., KRAMER R., HOTZE H.-J., VAN DER BEEK M., BLOM G., VALLET J.-P. et GORIEU O., “The harmonized European gas cubic meter for natural gas as realized by PTB, NMI-VSL and LNE-LADG and its benefit for users and metrology”, 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

KHELIFA N. et PINOT P., “Monitoring Air Moisture with Laser Absorption Spectroscopy”, 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007, article en ligne : arXiv:0705.0616.

MORGADO I., « Etalon primaire pour les débits de fuites de fluides frigorigènes », 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

MÜLLER H., CARE I. et SANCHEZ J.R., “LDA-based intercomparison anemometers”, 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

VALLET J.P., KERVEVAN P., PLATEL F. et LAURENT G., « Structure de la chaîne d’étalonnage française en débitmétrie gazeuse », 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

VEAU J. et BEDIAT N., « Evaluation de trois débitmètres électromagnétiques », 13e Congrès international de métrologie, Lille, France, 18-21 juin 2007.

RODRIGUES D., GUIANVARC’H C., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., « Méthode de mesure d'impédance de petits éléments acoustiques », 18e Congrès français de Mécanique, Grenoble, France, 27-31 août 2007.

RODRIGUES D., GUIANVARC’H C., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., “Input behaviour of small acoustic components: measurement procedure and its accuracy”, 19th International Congress on Acoustics, Madrid, Espagne, 2-7 septembre 2007.

SILVESTRI Z., PINOT P., ZERROUKI C., LAUSMAA J. et LECOLLINET M., “Surface characterization techniques for artefacts mass standards”, International School Quantum Metrology and Fundamental Constants, Les Houches, France, 1-12 octobre 2007.

MADEC T, “Rooms and equipements of the new mass laboratory of LNE”, Asia Pacific Symposium on Mass, Force and Torque (APMF 2007), Sydney, Australie, CD-Rom, 24-26 octobre 2007.

MORGADO I., « Etalon primaire pour les débits de fuites de fluides frigorigènes », Congrès du Cetiat, Villeurbanne, France, 21 novembre 2007.

AVERLANT PH., “Development of the new LNE 50 N.m deadweight torque standard machine”, 20th TC3 Imeko Congress, Merida, Mexique, 27-30 novembre 2007.

OTAL P., “Three Technologies met in the Pressure Range 0,5 Pa to 3 Pa absolute”, 20th TC3 Imeko Congress, Merida, Mexique, 27-30 novembre 2007.

ZERROUKI C., « Rugosité superficielle nanométrique : aspect multi-échelles et moyens de caractérisation », Rencontres Recherche – Industrie en nanométrologie, LNE, Paris, France, 29 novembre 2007.

Publications

KHELIFA N., “Micro force Measurement by optical method”, HAL-00327718, octobre 2008.

KHÉLIFA N., “Air Moisture Measurement: The Indiscreetness of the Dew-point Hygrometer” , Measurement Science Review, 8, 2008, 22-24.

KOCAS I., LEGRAS J.-C. et OTAL P., “Final report on EUROMET.M.P-S4: bilateral pressure comparison in gas media between LNE (France) and UME (Turkey) (gauge mode) in the range from 0.04 MPa to 1.75 MPa”, Metrologia, 45, Techn. Suppl., 2008, 07005.

LOREFICE S., MALENGO A., VÁMOSSY C., BETTIN H., TOTH H., DO CÉU FERREIRA M., GOSSET A., MADEC T., HEINONEN M., BUCHNER C., LENARD E., SPURNY R., AKCADAG U. et DOMOSTROEVA N., “EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations”, Metrologia, 45, Techn. Suppl., 2008, 07008.

MADEC T. et MEURY P.A., « Mesure de la masse volumique de l’air par méthode gravimétrique pour l’étalonnage de masses », Revue française de métrologie, 16, 2008, 15-19.

MEURY P.A. et MOLINS R., “Definition of a new metallic alloy for the realisation of secondary reference mass standard”, MAPAN - Journal of Metrology Society of India, 23, 3, 2008, 165-172.

OTAL P., HAREL D. et LEGRAS J-C., « Comparaison entre la balance de pression absolue et le manomètre à colonne de mercure du LNE », Revue française de métrologie, 13, 2008, 25-32.

OTAL P., LEGRAS J.-C., GOYON C., BARAT P. et DAVIS R.S., “Final report on supplementary comparison EUROMET.M.P-S3 of absolute pressure standards in the barometric range from 80 kPa to 110 kPa”, Metrologia, 45, Techn. Suppl., 2008, 07004.

RODRIGUES D., GUIANVARC'H C., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., “A method to measure and interpret input impedance of small acoustic components”, Journal of Sound and Vibration, 315, 2008, 890-910.

Communications

MEURY P.A., “Materials characterisation for reference mass standards”, Euramet TC-M 2008, Bucarest, Roumanie, 5-7 mars 2008.

MEURY P.A., “Micro-mass standards at LNE to determine the sensitivity error of comparators”, Euramet TC-M 2008, Bucarest, Roumanie, 5-7 mars 2008.

MEURY P.A., “Reference mass standards at LNE”, Euramet TC-M 2008, Bucarest, Roumanie, 5-7 mars 2008.

KHELIFA N., PINOT P. et LECOLLINET M., « L’hygromètre à point de rosée : un instrument non discret au sens du VIM-94 », CAFMET 2008, Tunis, Tunisie, 22-24 avril 2008.

MADEC T. et MEURY P.A., « Utilisation d'artefacts en métrologie de la masse au LNE pour la détermination des corrections de poussée d'air », CAFMET 2008, Tunis, Tunisie, 22-24 avril 2008.

RODRIGUES D., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.M., “Free-field calibration of microphones: theoretical and experimental determination of the acoustic center”, Acoustics'08, Paris, France, 29 juin - 4 juillet 2008.

MADEC T., ESCORIZA J., MEURY P.A. et MANN G., “Improvement of the characteristics of small weights by a change of shape and a better knowledge of density”, I CIMMEC, Rio de Janeiro, Brésil, 8-10 octobre 2008.

MORGADO I., LEGRAS J.-C. et CLODIC D., « Détecteur de fuite suivant EN 14624 : chaîne complete d’étalonnage et vérification », Colloque effet de serre VII - AFCE, Paris, France, 9 octobre 2008.

MAHE E., MADEC T. et MEGHARFI M., « Traçabilité des mesures de viscosité des biofuels », BioFuels MET 2008, Strasbourg, France, 6-7 novembre 2008.

FOURATI N., SILVESTRI Z., NASRALLAH H., ZERRAD M., ZERROUKI C, DE FORNEL F., DEUMIE C., AMRA C., DUCOURTIEUX S., PINOT P. et MONNOY S., “Towards nanoroughness standards with a continuum of spatial frequencies”, Journées nationales en nanosciences et nanotechnologies 2008, Grenoble, France, novembre 2008.

ZERROUKI C., PINOT P., DE FORNEL F., FOURATI N., NASRALLAH H., SILVESTRI Z., MONNOY S., ZERRAD M., DEUMIE C., AMRA C. et DUCOURTIEUX S., “Random Roughness Standards: Needs and Applications”, Journées nationales sur les technologies émergentes en micro-nanofabrication 2008, Toulouse, France, novembre 2008.

Publications

CAZAURAN X., HUCHET A., PIOGER J., GUYOT S., MORIO Y., DUCOMMUN N., RIOUT J., CRETIN S., RADET T. et MORGADO I., « Confinement des matériels frigorifiques », Les ouvrages du CETIM, ISBN : 978 2 85400-900-2.

MORGADO I., OTAL P. et CLODIC D., « Référence nationale pour la mesure des débits de fuites de R 134a », Revue générale du froid et du conditionnement d’air, 1092, 2009, 57-64.

OTAL P., LEGRAS J.-CL. et BOINEAU F., « Étalonnage des fuites d'hélium : méthodes de référence et dissémination de 10-10 Pa·m3·s-1 à 10-2 Pa·m3·s-1 », Revue française de métrologie, 17, 2009, 3-9.

RODRIGUES D., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., “A new method for the determination of the acoustic center of acoustic transducers”, Acta Acustica, à paraître en 2010, DOI : 10.3813/AAA.918279.

Communications

SILVESTRI Z., « Labview orchestre la mesure de la diffusion de la  lumière pour déterminer la rugosité de surface à l'échelle nanométrique », NIDays 2009, Port-Marly, France, 2 février 2009.

KHELIFA N., “Microforce measurement by an optical method”, Optical sensors 2009, Prague, République tchèque, 20-22 avril 2009, Proc. SPIE, 7356, 2009.

RODRIGUES D., « Comment se raccorde le décibel aux étalons internationaux ? », Journées « Faites de la mesure », Brüel & Kjær, Paris, France, 9-11 juin 2009.

AVERLANT P., LICHT T. et BARTOLI C., « Influence du montage mécanique sur les résultats d’étalonnage des accéléromètres en haute fréquence », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

BEAULIEU C., HEDAN O., DELLA BELLA C., HALOUA F. et FILTZ J.-R., « Traçabilité du comptage industriel de gaz naturel », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

CLAUDEL P., « Vers une nouvelle référence pour les petits débits de liquide », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

DAVID CH., VEAU J., CARE I., BEDIAT N. et TEIXEIRA V., « Evaluation de trois débitmètres à effet Coriolis », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

DU COLOMBIER D., HANNACHI R., PINOT P. et SILVESTRI Z., « Nouveau dispositif de mesure de l’adsorbabilité de gaz sur des matériaux utilisés en métrologie », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

KHELIFA N. et PINOT P., « Mesure de microforce par effet photoélastique dans un laser solide », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

LEODIDO L.M., SARRAF CH. et DAMION J.-P., « Caractéristiques dynamiques des capteurs de pression en milieu hydraulique », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

MORGADO I., OTAL P., LEGRAS J-CL. et CLODIC D., « Vers une traçabilité de la détection d’étanchéité des installations frigorigènes », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

SILVESTRI Z., PINOT P. et ZERROUKI C., « Rugosité d’un étalon de masse : évaluation de l’incertitude par une méthode de Monte Carlo », 14e Congrès international de métrologie, Paris, France, 22-25 juin 2009.

DAVID CH., “Development of a new reference for low flows of liquid (Water)”, European meeting on microflow metrology, PTB, Braunchsweig, Allemagne, 24-25 juin 2009.

DAVID CH., « Campagne d’évaluation de débitmètres à effet Coriolis », Journée technique de l’EXERA : Débitmètres et Anémomètres, Paris, France, 24-25 juin 2009.

TEIXEIRA V., « Campagne d’évaluation de débitmètres à turbine », Journée technique de l’EXERA : Débitmètres et Anémomètres, Paris, France, 24-25 juin 2009.

AVERLANT P. et BARTOLI C., “Upgrade of the medium and high frequency vibration calibration reference equipment and extension to low frequencies”, IMEKO XIXth world congress, Lisbonne, Portugal, 6-11 septembre 2009.

HANNACHI R., DU COLOMBIER D., PINOT P. et SILVESTRI Z.; “Use of mirage effect for the detection of adsorption of organic molecules on the surface of Pt-10%Ir alloy of mass standard”, IMEKO XIXth world congress, Lisbonne, Portugal, 6-11 septembre 2009.

MORGADO I., OTAL P., LEGRAS J-CL. et CLODIC D., “Traçability of refrigerant leak tightness”, IMEKO XIXth world congress, Lisbonne, Portugal, 6-11 septembre 2009.

SILVESTRI Z. et PINOT P., “Thermal desorption mass spectrometry (TDS). Application on mass metrology”, IMEKO XIXth world congress, Lisbonne, Portugal, 6-11 septembre 2009.

MORGADO I., OTAL P. et CLODIC D., « Traçabilité des performances des détecteurs frigorigènes », Colloque « Les rendez-vous du pole cristal », Dinan, France, 8-9 octobre 2009.

ZERROUKI C., SILVESTRI Z., FOURATI N., PINOT P., NASRALLAH H., DE FORNEL F., ZERAD M., DEUMIE C, AMRA C., MONNOY S. et DUCOURTIEUX S., « Phénomènes de surfaces à l’échelle nanométrique et moyens de caractérisation : vers des étalons de rugosité », Journées nationales en nanosciences et nanotechnologies, Toulouse, France, 21-23 octobre 2009.

ZERROUKI C., FOURATI N., SILVESTRI Z., PINOT P., NASRALLAH H., DE FORNEL F., ZERAD M., DEUMIE C, AMRA C., MONNOY S. et DUCOURTIEUX S., « Nanorugosité et référence ; intérêt de la densité spectrales de puissance », Journ. 2009 du GDR du CNRS « Ondes », Paris, France, 2-4 novembre 2009.

Publications

BARBE J., DIJOUX F., YARDIN C., MACE T. et VASLIN-REIMANN S., “Calibration and uncertainties in gas microflow measurement in the range of 2–200 μg s−1 of nitrogen”, Measurement Science and Technology, 21, 2010, DOI: 10.1088/0957-0233/21/7/074002.

LAVERGNE T., DURAND S., RODRIGUES D., BRUNEAU M. et JOLY N., “Dynamic behaviour of the circular membrane of an electrostatic microphone: effect of holes in the backing electrode”, J. Acoust. Soc. Am., 128, 6, 2010, 3459-3477.

MANN G., MADEC T. et MEURY P.-A., “CCM-M.K3-1 comparison / 50 kg mass”, Metrologia, 47, Tech. suppl., 2010, 07013.

MEURY P.-A., MOLINS R. et GENEVÈS G., “Metallurgical characterization of materials for the reference mass standard of the French watt balance experiment”, Metrologia, 47, 2010, 659-669.

MORGADO I., LEGRAS J.-CL. et CLODIC D., “Primary standard for the calibration of refrigerant leak flow rates”, Metrologia, 47, 3, 2010, 135-145.

RIBEIRO C., CELLARD P., ECOTIERE D., ANDRE C. et BARBO B., « Influence de la présence d'eau dans une protection anti-pluie sur la réponse d’un capteur acoustique - Estimation de l’incertitude de mesure associée », Acoustique & Techniques, 60, 2010, 39-45.

RODRIGUES D., DUROCHER J.-N., BRUNEAU M. et BRUNEAU A.-M., “A new method for the determination of the acoustic center of acoustic transducers”, Acta Acustica united with Acustica, 96, 2, 2010, 300-305.

SILVESTRI Z., DU COLOMBIER D., MACE S. et PINOT P., « Moyens de caractérisation des surfaces et leurs applications en métrologie », Revue française de métrologie, 23, 2010, 11-20.

Communications

OTAL P. « Métrologie des pressions », Afnor BiVi Métrologie, MTL-II-20-30, février 2010.

MORGADO I., « Métrologie des faibles débits de fuites s'écoulant à pression atmosphérique », Afnor BiVi Métrologie, MTL-II-20-21, avril 2010.

JOLY N., HONZIK P., RODRIGUES D., DUROCHER J.-N., DURAND S. et BRUNEAU M., « Modélisation numérique de l’acoustique en fluide thermovisqueux », 10e Congrès Francais d'Acoustique, Lyon, France, 12-16 avril 2010.

LAVERGNE T., RODRIGUES D., DURAND S. et BRUNEAU M., « Transducteurs réciproques du continu à 100 kHz : modélisation, comportement, applications », 10e Congrès Français d'Acoustique, Lyon, France, 12-16 avril 2010.

RIBEIRO C., CELLARD P., ECOTIERE D., ANDRE C. et BARBO B., « Influence de la présence d'eau dans une protection anti-pluie sur la réponse d'un capteur acoustique - Estimation de l'incertitude de mesure associée », 10e Congrès Francais d'Acoustique, Lyon, France, 12-16 avril 2010.

MADEC T. et AMAROUCHE S., “Comparison of micropipettes calibration by accredited laboratories”, International Metrology Conference CAFMET 2010, Le Caire, Egypte, 18-23 avril 2010.

PINOT P., MACE S. et GENEVES G., « Comportement statique et dynamique de matériaux utilisés comme pivots flexibles », Congrès Matériaux 2010, Nantes, 18-22 octobre 2010.

RODRIGUES D., HONZIK P., JOLY N., DUROCHER J.-N., DURAND S. et BRUNEAU M., “The finite elements modeling of the acoustics in thermo-viscous fluid: Application on the axisymetrical study of the artificial ear (IEC 60318-1)”, Internoise, Lisbonne, Portugal, 13-16 juin 2010.

DAVID Ch. et CLAUDEL P., “Novel Water Flow Facility In France - Range extension to low flow rates (10 000 ml/h down to 1 ml/h)”, FLOMEKO 2010, Taipei, Taiwan, 13-15 octobre 2010.

VALLET J.-P., KERVEVAN P. et OUERDANI A., “The ‘RCT’: two functions integrated in one for pressure regulation and gas flow metering”, FLOMEKO 2010, Taipei, Taiwan, 13-15 octobre 2010.

SILVESTRI Z., ZERROUKI C., FOURATI N., PINOT P., NASRALAH H. et DE FORNEL F., « Rugosité aux échelles nanométriques : caractérisation et stabilité à court et moyens termes », Congrès Matériaux 2010, Nantes, France, 18-22 octobre 2010.

BOINEAU F., « Métrologie des faibles flux gazeux référencés au vide », Afnor BiVi Métrologie, MTL-II-20-22, novembre 2010.

Publications

BARTOLI C., AVERLANT PH. et DE WAUBERT C., « Extension en basse fréquence et amélioration des incertitudes du banc d’étalonnage primaire des accéléromètres », Revue française de métrologie, 27, 2011, 21-28, DOI: 10.1051/rfm/2011010.

BOINEAU F. et OTAL P., « Réalisation d’une référence primaire pour la mesure de flux gazeux entre 4 x 10–12 mol·s–1 et 4 x 10–7 mol·s–1 », Revue française de métrologie, 24, 2010, 35-51.

BOINEAU F., “Characterization of the LNE constant pressure flowmeter for the leak flow rates measurements with reference to vacuum and atmospheric pressure”, PTB Mitteilungen, 121, 2011-3, 313-316.

DAVID CH. et CLAUDEL P., “Novel water flow facility in France- range extension to low flow rates (10 000 ml/h down to 1 ml/h)”, MAPAN, Journal of Metrology Society of India, 26, 3, 2011, 203-209, DOI: 10.1007/s12647-011-0019-0.

FAHD G., MOKHTAR O., BOIRON O., MORGADO I., PAGANELLI F., DEPLANO V. et AIT MOKHTAR O., “Comparing invasive and oscillometric blood pressure measurements”, Computer methods in biomechanics and biomedical engineering, 14, Suppl.1, 149-151, DOI: 10.1080/10255842.2011.593948.

OTAL P., “Evaluation of cross-float measurements with pressure balances”, PTB Mitteilungen, 121, 2011-3, 294-297.

SAXHOLM S. et OTAL P, “Traceability of the pressure balance effective area at MIKES”, PTB Mitteilungen, 121, 2011-3, 284-286.

VAN ANDEL I., BECERRA L.O., BICH W., BOGDANOV V., CHUNG J.W., DAVIDSON S., FEN K.M.K., FUCHS P., GLÄSER M., HONG Y., JABBOUR Z.J., JACQUES C., KUMAR A., LOAYZA V.M., MADEC T., MEDINA N., OOIWA A., RICHARD P., SNEGOV V., SPURNÝ R. et WISNIEWSKI W., “Report on CIPM key comparison of the second phase of multiples and submultiples of the kilogram (CCM.M-K5)”, Metrologia, 48, Techn. Suppl., 2011, 07008, DOI: 10.1088/0026-1394/48/1A/07008.

WONGTHEP P. et RABAULT T., “New model of fluid flow to determine pressure balance characteristics”, PTB Mitteilungen, 121, 2011-3, 270-273.

Communications

KHELIFA N., “Applying and measuring small force”, SENSOR+TEST Conferences 2011, Nuremberg, Allemagne, 7-9 juin 2011, DOI: 10.5162/sensor11/sp8.9.

CELLARD P., “The different types of information available to characterize the noise of products”, International-INCE Buy Quiet Symposium, Paris, France, 5-6 juillet 2011.

CELLARD P., “The shared responsibility in providing precise information on noise levels between test laboratories, manufacturers, and authorities”, International-INCE Buy Quiet Symposium, Paris, France, 5-6 juillet 2011.

BARTOLI C., BEUG F., BRUNS T., ELSTER C., ESWARD T., KNOT A., KOBUSCH M. et SCHLEGEL C., “Traceable dynamic measurement of mechanical quantities: a new European collaborative project”, 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

DAVID Ch., “Evaluation of water flow measurement performance of clamp-on ultrasonic flowmeter technology”, 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

DAVID CH., LOTTERS J. et CLAUDEL P., “French water flow calibration facility, first experimental results at low flow rate”, 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

FAHD G., MORGADO I., AIT MOKHTAR O., BOIRON O., PAGANELLI F., OTAL P. et DEPLANO V, “Creating a calibrating chain in order to evaluate automated blood pressure devices”, 15e Congrès international de métrologie, Paris, France, 3-6 oct. 2011.

KHELIFA N., « Electro-mechanical device for generating small forces », 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

PINOT P. et MACE S., « Une chambre à vide modulable pour la métrologie française », 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

SILVESTRI Z., PINOT P. et MACE S., « Conservation d’étalons de masse sous vide ou gaz neutre par l’utilisation de moyens adaptés », 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

Publications

AFLALO E., DUPONT F., CELLARD P. et DUROCHER J.-N., « Une méthode automatique de détection des défauts d’une chaîne de mesure sonométrique utilisée lors de mesures de bruit sans surveillance », Acoustiques et Techniques, 68, 2012, 63-68.

BARBE J., DIJOUX F., YARDIN C. et MACÉ T., “Measurement of Helium micro flows for gas chromatography by the dilution method”, MAPAN, 27, 2, 2012, 77-81, DOI: 10.1007/s12647-012-0015-z.

FAHD G., BOIRON O., MORGADO I., PAGANELLI F., DEPLANO V., AIT MOKHTAR O. et OTAL P., “Design of a secondary standard for measuring arterial blood pressure”, Measurement, 45, 10, 2012, DOI: 10.1016/j.measurement.2011.10.033.

HONZiK P., JOLY N., DURAND S., RODRIGUES D., DUROCHER J.-N. et BRUNEAU M., “Finite element modelling of acoustic field inside small components: application to an annular slit terminated by an aperture in an infinite screen”, Metrologia, 49, 1, 2012, 32-40, DOI: 10.1088/0026-1394/49/1/006.

LEGRAS J.-C. et OTAL P., « Hautes pressions – Domaine de 50 MPa à 2 GPa », Techniques de l’ingénieur, R 2 060v2, 2012.

PINOT P. et GENEVÈS G., “Preliminary investigation of the damping effect of bubble levels used in dynamic conditions”, European Physical Journal Applied Physics, 60, 1, 2012, 11101, DOI: 10.1051/epjap/2012120230.

PLIMMER M., DU COLOMBIER D., IRAQI HOUSSAINI N., SILVESTRI Z., PINOT P. et HANNACHI R., “Apparatus to measure adsorption of condensable solvents on technical surfaces by photothermal deflection”, Review of Scientific Instruments, 83, 2012, DOI: 10.1063/1.4767245.

SABUGA W., OLSON D.A., TORRES J.C., YADAV S., JIN Y., KOBATA T., et OTAL P., “Final report on key comparison CCM.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure”, Metrologia, 49, Technical Supplement, 2012, 07006, DOI: 10.1088/0026-1394/49/1A/07006.

SABUGA W., PRIRUENROM T., MOLINAR MIN BECIET G., GIOVINCO G., RABAULT TH., WONGTHEP P. et PRAZÁK D., “FEA calculation of pressure distortion coefcients of gas-operated pressure balances – EURAMET project 1039”, Measurement, 45, 10, Special Volume, 2012, 2464-2468, DOI: 10.1016/j.measurement.2011.10.035.

VINCKE W., ZHIMIN Z., PUSA A., AVERLANT PH., KUMME R., GERMAK A., UEDA K., PARK Y.-K., TORRES J., BURKE B., LANGMEAD F., FANK S., KNOTT A. et BARTEL T., “Final report on force key comparison CCM.F-K2.a and CCM.F-K2.b (50 kN and 100 kN)”, Metrologia, 49, Techn. Suppl., 2012, 07002, DOI: 10.1088/0026-1394/49/1A/07002.

Communications

AFLALO E., DUPONT F., CELLARD P. et DUROCHER J.-N., “An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements”, Acoustics 2012, Nantes, France, 23–27 avril 2012.

DAVID CH., “Evaluation of water flow measurement performance of portable ultrasonic flowmeter technology”, 8th International Symposium on Fluid Flow Measurement, Colorado Springs, États-Unis, 20–22 juin 2012.

DAVID CH. et CLAUDEL P., “New primary standard for water flow calibration”, 8th International Symposium on Fluid Flow Measurement, Colorado Springs, États-Unis, 20–22 juin 2012.

KERVEVAN P., MANROT P., VALLET J.-P. et WINDENBERGER CH., “The conception and the construction of a new high pressure primary facility for gas”, 8th International Symposium on Fluid Flow Measurement, Colorado Springs, États-Unis, 20–22 juin 2012.

RODRIGUES D. et DUROCHER J.-N., “Methods for determining the free-field sensitivity of ½’’ working standard microphones by substitution”, Internoise, New York, États-Unis, 19–22 août 2012.

BARTOLI C., BEUG F., BRUNS T., ELSTER C., ESWARD T., KLAUS L., KNOTT A., KOBUSCH M., SAXHOLM S. et SCHLEGEL CH., “Traceable dynamic measurement of mechanical quantities: objectives and first results of this european project”, XX IMEKO World Congress, Busan, Corée du Sud, 9–14 septembre 2012.

DAVID CH., CLAUDEL P. et LÖTTERS J.-C., “Water flow calibration facility in France (1 ml/h to 10 000 ml/h)”, Micro Fluidic Handeling System conference, Enschede, Pays Bas, 10–12 octobre 2012.

DAVID CH., LECOFFRE Y., DUPUY J.-L., LOTTERS J. et CLAUDEL P., “Micro Flow Meters Calibration Test Loop at CETIAT (1 ml/h to 10 000 ml/h)”, 3rd European Conference on microfluidics, Heidelberg, Allemagne, 3–5 décembre 2012.