The International Temperature Scale 1990 (ITS-90) is the current internationally recognized temperature scale in use worldwide. After the redefinition of the kelvin via the Boltzmann constant, the ITS-90 will continue to be used as a robust and reliable tool. However, it has some limitations and pending issues that need to be resolved.

Objectives

Development of new advanced techniques to improve the traceability of the current definition of the kelvin, before the redefinition of 2018

Establish traceability to the SI according to the new definition, in order to support the widest and simplest dissemination of the temperature unit to end users

Summary

Find here the detailled description of the project:

http://www.notedproject.com/

Publications and communications

 

CAPPELLA C., SPARASCI F., PITRE L., BUÉE B. et EL MATARAWY A., “Improvements in the realization of the triple point of water in metallic sealed cells at LNE-Cnam”, Int. J. Metrol. Qual. Eng., 6, 4, 2015, DOI: 10.1051/ijmqe/2015026.

BUÉE B., VERGÉ A., VIDAL V., GEORGIN E. et SPARASCI F., “Copper passivation procedure for water-filled copper cells for applications in metrology”, Rapport du projet MeteoMet, http://arxiv.org/abs/1211.7294, novembre 2012.

KOZLOVA O., RONGIONE L. et BRIAUDEAU S., « Estimation des erreurs d’étalonnage de thermomètres infrarouges industriels liés à la méconnaissance de l’émissivité de sources et des bandes spectrales de thermomètres infrarouges », 17e Congrès international de métrologie, Paris, France, 21-24 septembre 2015, DOI: 10.1051/metrology/20150015010.

KOZLOVA O., SADOUNI A., TRUONG D.et BRIAUDEAU S., “A new tuneable IR radiation thermometer”, NOTED final workshop, Bruxelles, Belgique,  5-6 May 2015

CAPPELLA C., “New ITS-90 fixed points designs to study the thermal effects on TPs of O2, Ar, Hg and H2O”, NOTED final workshop, Bruxelles, Belgique,  5-6 May 2015

SPARASCI F., “New fixed points below the TPW”, NOTED final workshop, Bruxelles, Belgique,  5-6 May 2015

SPARASCI F., PITRE L., “Procedures for the calibration of SPRTs with respect to T in the temperature range between 77 K and 300 K NOTED final workshop, Bruxelles, Belgique,  5-6 May 2015

BRIAUDEAU S., SADOUNI A., KOZLOVA O., TRUONG D., BOURSON F., SADLI M., “Performances of the innovative portable spectroradiometer: fast wide-range tunability and high reproducibility”, NEWRAD 2014, Helsinki, Finlande,  24-27 June 2014

DEL CAMPO D. et al. , “A Multi-Institute European Project for Providing Improved and Simpler Traceability to the Kelvin”, International congress of Metrology, 2013, Paris, France,  7th-10th October 2013, DOI: 10.1051/metrology/201315006

VIDAL V., VERGE A., MARTIN C., BUE B., SPARASCI F., “Calorimetric Quasi-Adiabatic Realization of the Triple Point Of Water At LCM LNE/CNAM”, Tempmeko 2013, Funchal, Madère, Portugal, 14-18 Octobre 2013

FIORILLO D., VERGÉ A., MARTIN C., BARBOTIN V., HERMIER Y., SPARASCI F., “New calorimeter for SPRT calibrations at argon and oxygen fixed points: further improvements at LNE-CNAM”, Tempmeko 2013, Funchal, Madère, Portugal, 14-18 Octobre 2013

SADOUNI A., « Réalisation et caractérisation métrologique d’un pyromètre accordable », CNAM, Saint-Denis, France, 11 décembre 2015

Partners

  • CEM (ES),
  • CMI (CZ),
  • INRiM (IT),
  • IPQ (PT),
  • MKEH (HU),
  • NPL (GB),
  • PTB (DE),
  • SMD (BE),
  • TUBITAK (TR),
  • UL (SI),
  • VSL (NL)

Related projects

Vers la mise en pratique de la constante de Boltzmann : la température dans les échelles en basses températures

Ce projet vise à mettre en place les références nationales dans le domaine 0,65 K à 24 K, établir l’écart entre T90 et la température thermodynamique mesurée par thermométrie acoustique dans les gaz, entre 0,65 K et 273 K et établir et valider les budgets d’incertitudes sur la réalisation de l’Echelle internationale de température de 1990 (EIT-90) en dessous de 273 K.