Publications

BATTUELLO M., FLORIO M., SADLI M. et BOURSON F., “Investigations on two Co-C fixed-point cells prepared at INRIM and LNE-Cnam”, International Journal of Thermophysics, 32, 7-8, 2011, 1732-1743, DOI: 10.1007/s10765-011-0971-5.

BOURSON F., SADLI M., ROUGIÉ B. et BRIAUDEAU S., “Study and comparison of newly developed ITS-90 Silver- and Copper-point cells”, International Journal of Thermophysics, 32, 7-8, 2011, 1602- 1610, DOI: 10.1007/s10765-011-0974-2.

BRIAUDEAU S., SADLI M., BOURSON F., ROUGIÉ B., RIHAN A., et ZONDY J-J., “Primary radiometry for the mise-en-pratique: The laser-based radiance method applied to a pyrometer”, International Journal of Thermophysics, 32, 11-12, 2011, 2183-2196, DOI: 10.1007/s10765-011-1129-1.

OGURA H., FAVREAU J.-O., DEUZE T. et MORICE R., “Comparison of Co–C and Pd–C eutectic-point cells for thermocouple calibration between LNE-Cnam and NMIJ”, International Journal of Thermophysics, 32, 7-8, 2011, 1811-1823, DOI: 10.1007/s10765-011-1022-y.

PEARCE J., EDLER F., ELLIOTT C., FAILLEAU G., MORICE R. et OGURA H., “Investigation of Pd-C cells to improve thermocouple calibration”, Metrologia, 48, 2011, 375-381, DOI: 10.1088/0026-1394/48/5/019.

PITRE L., SPARASCI F., TRUONG D., GUILLOU A., RISEGARI L. et HIMBERT M.E., “Determination of the Boltzmann constant using a quasi-spherical acoustic resonator”, Phil. Trans. R. Soc. A, 369, 2011, 4014-4027, DOI: 10.1098/rsta.2011.0197.

PITRE L., SPARASCI F., TRUONG D., GUILLOU A., RISEGARI L. et HIMBERT M.E., “Measurement of the Boltzmann Constant kB Using a Quasi-Spherical Acoustic Resonator”, International Journal of Thermophysics, 32, 2011, 1825-1886, DOI: 10.1007/s10765-011-1023-x.

PUŠNIK I., CLAUSEN S., FAVREAU J.-O., GUTSCHWAGER B., DOĞAN A.K., DIRIL A., GUVEN O.P., MCEVOY H., HOEM S.S., STEINER A. et VAN DER HAM E., “Comparison of blackbodies for calibration of infrared ear thermometers”, International Journal of Thermophysics, 32, 1-2, 2011, 127-138, DOI: 10.1007/s10765-011-0928-8.

RIHAN A., ANDRIEUX E., ZANON-WILLETTE T., BRIAUDEAU S., HIMBERT M. et ZONDY J.-J., “A pump-resonant signal-resonant optical parametric oscillator for spectroscopic breath analysis”, Appl Phys B, 102, 2, 2011, 367-374, DOI: 10.1007/s00340-010-3996-8.

SADLI M., BLOEMBERGEN P., KHLEVNOY B., WANG T., YAMADA Y. et MACHIN G., “An international study of the long-term stability of metal–carbon eutectic cells”, International Journal of Thermophysics, 32, 7-8, 2011, 1786–1799, DOI: 10.1007/s10765-011-1009-8.

SADLI M., MATVEYEV M., BOURSON F., FUKSOV V., SILD Y.A. et POKHODUN A., “Comparison of pyrometric Co-C and Re-C eutectic-point cells between VNIIM and LNE-Cnam”, International Journal of Thermophysics, 32, 11-12, 2011, 2657-2670, DOI: 10.1007/s10765-011-1079-7.

SPARASCI F., PITRE L., ROUILLE G., THERMEAU J.-P., TRUONG D., GALET F. et HERMIER Y., “An adiabatic calorimeter for the realization of the ITS-90 in the cryogenic range at the LNE-CNAM”, International Journal of Thermophysics, 32, 2011, 201-214, DOI: 10.1007/s10765-011-0941-y.

SPARASCI F., PITRE L., TRUONG D., RISEGARI L. et HERMIER Y., “Realization of a 3He–4He vapor-pressure thermometer for temperatures between 0.65 K and 5 K at LNE-CNAM”, International Journal of Thermophysics, 32, 2011, 139-152, DOI: 10.1007/s10765-011-0929-7.

TRUONG D., SPARASCI F., FOLTETE E., OUISSE M. et PITRE L., “Measuring shell resonances of spherical acoustic resonators”, International Journal of Thermophysics, 32, 2011, 427-440, DOI: 10.1007/s10765-010-0846-1.

Communications

PITRE L., SPARASCI F., GUILLOU A., TRUONG D. et RISEGARI L., “The Boltzmann constant from the speed of sound in a non-quite spherical cavity”, The new SI: units of measurement based on fundamental constants, The Royal Society, Londres, Royaume-Uni, 24-25 janvier 2011.

SADLI M., “Current and future high temperature measurements challenges for the nuclear industry, in high temperature”, Measurement Workshop ESTEC, Noordwijk, Pays-Bas, 9 mars 2011.

SPARASCI F., PITRE L., GUILLOU A., TRUONG D. et RISEGARI L., “Towards the mise en pratique of the Boltzmann constant in thermometry at the LNE-CNAM”, NIST, 28 mars 2011.

SADLI M., BRIAUDEAU S. et HERMIER Y., “High-temperature metrology: challenges and potential solutions”, Congrès international “Materials and Fluids at High Temperature” (MFHT4), Orléans, France, 30-31 mars et 1er avril 2011.

MATVEYEV M., SADLI M., SILD Y. A., BOURSON F. et FUKSOV V., “High temperature fixed point and scale realisation comparisons between VNIIM and LNE-CNAM: report on six years of collaboration, 4th All-Russian Conference On Thermometry (Temperature 2011), Saint-Petersbourg, Russie, 19-21 avril 2011.

FAILLEAU G., DEUZE T., ELLIOTT C., PEARCE J., MACHIN G., BRIAUDEAU S. et SADLI M., “Development of an Fe-C eutectic fixed-point for the calibration and in-situ monitoring of thermocouples”, 2nd IMEKO TC 11 International Symposium Metrological Infrastructure, Cavtat, Croatie, 15-17 juin 2011.

JOHANSSON L., FILTZ J-R., DE FELICE P., SADLI M., PLOMPEN A., HAY B., DINSDALE A., POMMÉ S., CASSETTE PH. et KEIGHTLEY J., “Advanced metrology for new generation nuclear power plants”, 2nd IMEKO TC 11 International Symposium Metrological Infrastructure, Cavtat, Croatie, 15-17 juin 2011.

SADLI M., “HiTeMS/WP4 Validated methods for non-contact thermometry above 2500 °C including novel correction techniques – overview of work plan”, EMRP Kick-off meeting of the JRP-IND01, NPL, Teddington, Royaume-Uni, 13-15 septembre 2011.

SADLI M., DEL CAMPO D., DE PODESTA M., FAILLEAU G., FOURREZ S., GARCIA C., PEARCE J., RAE C. et SCERVINI M., “Improving high temperature measurements for the nuclear industry at the european level”, 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

SADLI M., BOURSON F., BRIAUDEAU S., DEUZE T., FAILLEAU G., AGNANDJI E., OJANEN M. et ROUGIÉ B., “Review and prospects of the high temperature metrology activities at LNE-Cnam”, 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

MACHIN G., ANHALT K., EDLER F., PEARCE J., SADLI M., STRNAD R. et VUELBAN E., “HITEMS: a pan-european project to solve high temperature measurement problems in industry”, 15e Congrès international de métrologie, Paris, France, 3-6 octobre 2011.

SADLI M., DEL CAMPO D., ELLIOTT C., GARCIA C., DE PODESTA M., FAILLEAU G., FOURREZ S., PEARCE J., RAE C. et SCERVINI M., “METROFISSION: High temperature metrology for the next generation nuclear power plants”, 3e Groupe de travail “Metering of feed-water flow, temperature and thermal power” organisé par SP et EDF, Chatou, France, 10-12 octobre 2011.

SPARASCI F., “MeteoMet Work Package 2: Novel methods, instruments and measurements for climate parameters”, EMRP MeteoMet kick-off meeting, Turin, Italie, 12-13 octobre 2011.

SPARASCI F., “MeteoMet Task 2.2: Novel methods and instruments for atmospheric humidity measurement”, EMRP MeteoMet kick-off meeting, Turin, Italie, 12-13 octobre 2011.

SADLI M., “High-temperature fixed points for radiation thermometry”, Euramet TC-T Workshop “Uncertainties in thermometric fixed points & SPRT calibrations”, SMD, Bruxelles, Belgique, 27-28 octobre 2011.