Publications

AFLALO E., DUPONT F., CELLARD P. et DUROCHER J.-N., « Une méthode automatique de détection des défauts d’une chaîne de mesure sonométrique utilisée lors de mesures de bruit sans surveillance », Acoustiques et Techniques, 68, 2012, 63-68.

BARBE J., DIJOUX F., YARDIN C. et MACÉ T., “Measurement of Helium micro flows for gas chromatography by the dilution method”, MAPAN, 27, 2, 2012, 77-81, DOI: 10.1007/s12647-012-0015-z.

FAHD G., BOIRON O., MORGADO I., PAGANELLI F., DEPLANO V., AIT MOKHTAR O. et OTAL P., “Design of a secondary standard for measuring arterial blood pressure”, Measurement, 45, 10, 2012, DOI: 10.1016/j.measurement.2011.10.033.

HONZiK P., JOLY N., DURAND S., RODRIGUES D., DUROCHER J.-N. et BRUNEAU M., “Finite element modelling of acoustic field inside small components: application to an annular slit terminated by an aperture in an infinite screen”, Metrologia, 49, 1, 2012, 32-40, DOI: 10.1088/0026-1394/49/1/006.

LEGRAS J.-C. et OTAL P., « Hautes pressions – Domaine de 50 MPa à 2 GPa », Techniques de l’ingénieur, R 2 060v2, 2012.

PINOT P. et GENEVÈS G., “Preliminary investigation of the damping effect of bubble levels used in dynamic conditions”, European Physical Journal Applied Physics, 60, 1, 2012, 11101, DOI: 10.1051/epjap/2012120230.

PLIMMER M., DU COLOMBIER D., IRAQI HOUSSAINI N., SILVESTRI Z., PINOT P. et HANNACHI R., “Apparatus to measure adsorption of condensable solvents on technical surfaces by photothermal deflection”, Review of Scientific Instruments, 83, 2012, DOI: 10.1063/1.4767245.

SABUGA W., OLSON D.A., TORRES J.C., YADAV S., JIN Y., KOBATA T., et OTAL P., “Final report on key comparison CCM.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure”, Metrologia, 49, Technical Supplement, 2012, 07006, DOI: 10.1088/0026-1394/49/1A/07006.

SABUGA W., PRIRUENROM T., MOLINAR MIN BECIET G., GIOVINCO G., RABAULT TH., WONGTHEP P. et PRAZÁK D., “FEA calculation of pressure distortion coefcients of gas-operated pressure balances – EURAMET project 1039”, Measurement, 45, 10, Special Volume, 2012, 2464-2468, DOI: 10.1016/j.measurement.2011.10.035.

VINCKE W., ZHIMIN Z., PUSA A., AVERLANT PH., KUMME R., GERMAK A., UEDA K., PARK Y.-K., TORRES J., BURKE B., LANGMEAD F., FANK S., KNOTT A. et BARTEL T., “Final report on force key comparison CCM.F-K2.a and CCM.F-K2.b (50 kN and 100 kN)”, Metrologia, 49, Techn. Suppl., 2012, 07002, DOI: 10.1088/0026-1394/49/1A/07002.

Communications

AFLALO E., DUPONT F., CELLARD P. et DUROCHER J.-N., “An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements”, Acoustics 2012, Nantes, France, 23–27 avril 2012.

DAVID CH., “Evaluation of water flow measurement performance of portable ultrasonic flowmeter technology”, 8th International Symposium on Fluid Flow Measurement, Colorado Springs, États-Unis, 20–22 juin 2012.

DAVID CH. et CLAUDEL P., “New primary standard for water flow calibration”, 8th International Symposium on Fluid Flow Measurement, Colorado Springs, États-Unis, 20–22 juin 2012.

KERVEVAN P., MANROT P., VALLET J.-P. et WINDENBERGER CH., “The conception and the construction of a new high pressure primary facility for gas”, 8th International Symposium on Fluid Flow Measurement, Colorado Springs, États-Unis, 20–22 juin 2012.

RODRIGUES D. et DUROCHER J.-N., “Methods for determining the free-field sensitivity of ½’’ working standard microphones by substitution”, Internoise, New York, États-Unis, 19–22 août 2012.

BARTOLI C., BEUG F., BRUNS T., ELSTER C., ESWARD T., KLAUS L., KNOTT A., KOBUSCH M., SAXHOLM S. et SCHLEGEL CH., “Traceable dynamic measurement of mechanical quantities: objectives and first results of this european project”, XX IMEKO World Congress, Busan, Corée du Sud, 9–14 septembre 2012.

DAVID CH., CLAUDEL P. et LÖTTERS J.-C., “Water flow calibration facility in France (1 ml/h to 10 000 ml/h)”, Micro Fluidic Handeling System conference, Enschede, Pays Bas, 10–12 octobre 2012.

DAVID CH., LECOFFRE Y., DUPUY J.-L., LOTTERS J. et CLAUDEL P., “Micro Flow Meters Calibration Test Loop at CETIAT (1 ml/h to 10 000 ml/h)”, 3rd European Conference on microfluidics, Heidelberg, Allemagne, 3–5 décembre 2012.