Publications

ANDREASSON U., GOBOM J., DELATOUR V., AUCLAIR G., NOAM Y., LEE S., WEN J., JEROMIN A., ARSLAN B., MACESKI A., WILLEMSE E., ZETTERBERG H., KUHLE J. et BLENNOW K., "Assessing the commutability of candidate reference materials for the harmonization of neurofilament light measurements in blood", Clinical Chemistry and Laboratory Medicine (CCLM), 61, 7, 2023, 1245‑1254, DOI: 10.1515/cclm-2022-1181.

BASTARDO-FERNÁNDEZ I., CHEKRI R., NOIREAUX J., FISICARO P. et JITARU P., "Characterisation and quantification of titanium dioxide nanoparticles in food simulants by single particle inductively coupled plasma-tandem mass spectrometry using a high efficiency sample introduction system", Spectrochimica Acta Part B: Atomic Spectroscopy, 208, 2023, 106782, DOI: 10.1016/j.sab.2023.106782.

BAUDIN B., BIGOT É., BŒUF A., DELATOUR V., GIANGRANDE C., GRUSON D., GRZYCH G., LE GOFF C., MAILLOUX A., PEOC’H K., PIÉRONI L., SAPIN V., TABALANI H. et VAUBOURDOLLE M., "Feedback from Euromedlab 2023 for Seniors", Annales de Biologie Clinique, 81, 4, 2023, 435‑447, DOI: 10.1684/abc.2023.1822.

BESCOND A., OSTER C., FISICARO P., GODDARD S., QUINCEY P., TSAKANIKA L-A., LYMPEROPOULOU T. et OCHSENKUEHN-PETROPOULOU M., "Method for Preparation of a Candidate Reference Material of PM10 and PM2.5 Airborne Particulate Filters Loaded with Incineration Ash-Inter Comparison Results for Metal Concentrations", Atmosphere, 12, 1, 2023, 67, DOI: 10.3390/atmos12010067.

WIELGOSZ R., FORGAN B., DEL CAMPO MALDONADO D., REA A., WOOLLIAMS E., FULFORD J., MADONNA F.,  WHETSTONE J., DECOLA P., VERMEULEN A., FLORES E., RUEDI I., 2023, DOI: 10.59161/Rapport202303

BUCHTA C., KOLLROS D., JOVANOVIC J., HUF W., DELATOUR V., PUCHHAMMER-STÖCKL E., MAYERHOFER M., MÜLLER MM., SHENOY S., GRIESMACHER A., ABERLE SW., GÖRZER I. et CAMP JV., "Converting to an international unit system improves harmonization of results for SARS-CoV-2 quantification: Results from multiple external quality assessments", Journal of Clinical Virology, 158, 2023, 105352, DOI: 10.1016/j.jcv.2022.105352.

CAPITAINE G., STOICA D., WAGENER T. et FISICARO P., "Production of a reference material for seawater pHT measurements by a National Metrology Institute", Marine Chemistry, 252, 2023, 104244, DOI: 10.1016/j.marchem.2023.104244.

CAVALIER E., FARRÉ-SEGURA J., LUKAS P., GENDEBIEN A-S., PEETERS S., MASSONNET P., LE GOFF C., BOUQUEGNEAU A., SOUBERBIELLE J-C., DELATOUR V. et DELANAYE P., "Unveiling a new era with liquid chromatography coupled with mass spectrometry to enhance parathyroid hormone measurement in patients with chronic kidney disease", Kidney International, 105, 2, 2024, 338‑346, DOI: 10.1016/j.kint.2023.09.033.

DIKAIOS I., ALTHAUS H., ANGLES-CANO E., CEGLAREK U., COASSIN S., COBBAERT CM., DELATOUR V., DIEPLINGER B., GRIMMLER M., HOOFNAGLE AN., KOSTNER GM., KRONENBERG F., KUKLENYIK Z., LYLE AN., PRINZING U., RUHAAK LR., SCHARNAGL H., VESPER HW. et DEPREZ L., "Commutability Assessment of Candidate Reference Materials for Lipoprotein(a) by Comparison of a MS-based Candidate Reference Measurement Procedure with Immunoassays", Clinical Chemistry, 69, 3, 2023, 262‑272, DOI: 10.1093/clinchem/hvac203.

F. -X. OUF, S. CHAZELET, G. FAVRE, N. FELTIN, V. LEMARINIER, V. GODEFERT, N. LAMBENG, J. MAST, J. NOIREAUX, C. OSTER, S. PACAULT, X. POISSON et C. WOUTERS, "RELARGAGE DE NANO-OBJETS, LEURS AGRÉGATS ET AGGLOMÉRATS DEPUIS LES MASQUES (RENAAME) : VALIDATION D’UNE MÉTHODE DE « CRIBLAGE » POUR L’IDENTIFICATION DES ÉLÉMENTS TI ET AG DANS LES MASQUES", 2024, DOI: 10.25576/ASFERA-CFA2024-38823.

FOUQUEAU A., POURCHEZ J., LECLERC L., PEYRON A., MONTIGAUD Y., VERHOEVEN P., MACÉ T., BESCOND A., THOMAS D., CHARVET A., GHIJSELING M., HARS P., POLYN F. et GAIE-LEVREL F., "Inter-laboratory Comparison between Particle and Bacterial Filtration Efficiencies of Medical Face Masks in the COVID-19 Context", Aerosol and Air Quality Research, 23, 2, 2023, 220252, DOI: 10.4209/aaqr.220252.

GIANGRANDE C., DELATOUR V., ANDREASSON U., BLENNOW K., GOBOM J. et ZETTERBERG H., "Harmonization and standardization of biofluid‐based biomarker measurements for AT(N) classification in Alzheimer’s disease", Alzheimer’s & Dementia: Diagnosis, Assessment & Disease Monitoring, 15, 3, 2023, e12465, DOI: 10.1002/dad2.12465.

GIANGRANDE C., VANEECKHOUTTE H., BOEUF A., LALERE B., HIRTZ C., LEHMANN S., QUAGLIA M. et DELATOUR V., "Development of a candidate reference measurement procedure by ID-LC-MS/MS for total tau protein measurement in cerebrospinal fluid (CSF)", Clinical Chemistry and Laboratory Medicine (CCLM), 61, 7, 2023, 1235‑1244, DOI: 10.1515/cclm-2022-1250.

GIANGRANDE C., VANEECKHOUTTE H., HIRTZ C., LEHMANN S., JEROMIN A. et DELATOUR V., "Routes to standardisation for tau protein measurement in CSF", Alzheimer’s & Dementia, 19, S14, 2023, e076172, DOI: 10.1002/alz.076172.

HUBER MJ., IVLEVA NP., BOOTH AM., BEER I., BIANCHI I., DREXEL R., GEISS O., MEHN D., MEIER F., MOLSKA A., PAROT J., SØRENSEN L., VELLA G., PRINA-MELLO A., VOGEL R. et CAPUTO F., "Physicochemical characterization and quantification of nanoplastics: applicability, limitations and complementarity of batch and fractionation methods", Analytical and Bioanalytical Chemistry, 415, 15, 2023, 3007‑3031, DOI: 10.1007/s00216-023-04689-5.

LAMAS B., CHEVALIER L., GAULTIER E., CARTIER C., WEINGARTEN L., BLANC X., FISICARO P., OSTER C., NOIREAUX J., EVARISTE L., BREYNER NM. et HOUDEAU E., "The food additive titanium dioxide hinders intestinal production of TGF-β and IL-10 in mice, and long-term exposure in adults or from perinatal life blocks oral tolerance to ovalbumin", Food and Chemical Toxicology, 179, 2023, 113974, DOI: 10.1016/j.fct.2023.113974.

MILLER WG., KELLER T., BUDD J., JOHANSEN JV., PANTEGHINI M., GREENBERG N., DELATOUR V., CERIOTTI F., DEPREZ L., REJ R., CAMARA JE., MACKENZIE F., LYLE AN., VAN DER HAGEN E., BURNS C., FAUSKANGER P., SANDBERG S., et FOR THE IFCC WORKING GROUP ON COMMUTABILITY IN METROLOGICAL TRACEABILITY, "Recommendations for Setting a Criterion for Assessing Commutability of Secondary Calibrator Certified Reference Materials", Clinical Chemistry, 69, 9, 2023, 966‑975, DOI: 10.1093/clinchem/hvad104.

MIRMONT E., BŒUF A., CHARMEL M., LALÈRE B. et LARDY-FONTAN S., "Validation of an isotope dilution mass spectrometry (IDMS) measurement procedure for the reliable quantification of steroid hormones in waters", Analytical and Bioanalytical Chemistry, 415, 16, 2023, 3215‑3229, DOI: 10.1007/s00216-023-04698-4.

RUHAAK LR., ROMIJN FPHTM., BEGCEVIC BRKOVIC I., KUKLENYIK Z., DITTRICH J., CEGLAREK U., HOOFNAGLE AN., ALTHAUS H., ANGLES-CANO E., COASSIN S., DELATOUR V., DEPREZ L., DIKAIOS I., KOSTNER GM., KRONENBERG F., LYLE A., PRINZING U., VESPER HW. et COBBAERT CM., "Development of an LC-MRM-MS-Based Candidate Reference Measurement Procedure for Standardization of Serum Apolipoprotein (a) Tests", Clinical Chemistry, 69, 3, 2023, 251‑261, DOI: 10.1093/clinchem/hvac204.

SANDBERG S., FAUSKANGER P., JOHANSEN JV., KELLER T., BUDD J., GREENBERG N., REJ R., PANTEGHINI M., DELATOUR V., CERIOTTI F., DEPREZ L., CAMARA JE., MACKENZIE F., LYLE AN., VAN DER HAGEN E., BURNS C., GREG MILLER W., et FOR THE IFCC WORKING GROUP ON COMMUTABILITY IN METROLOGICAL TRACEABILITY, "Recommendations for Setting a Criterion and Assessing Commutability of Sample Materials Used in External Quality Assessment/Proficiency Testing Schemes", Clinical Chemistry, 69, 11, 2023, 1227‑1237, DOI: 10.1093/clinchem/hvad135.

SIMON CG., BORGOS SE., CALZOLAI L., NELSON BC., PAROT J., PETERSEN EJ., ROESSLEIN M., XU X. et CAPUTO F., "Orthogonal and complementary measurements of properties of drug products containing nanomaterials", Journal of Controlled Release, 354, 2023, 120‑127, DOI: 10.1016/j.jconrel.2022.12.049.

TSE CY., ZHANG L., DAHYA K., POKUAH F., SUGAHARA O., DELATOUR V., DANILENKO U. et VESPER HW., "B-185 High Throughput ID-LCMSMS Method for Simultaneous Quantitation of Monosaccharides in Human Serum", Clinical Chemistry, 69, Supplement_1, 2023, hvad097.516, DOI: 10.1093/clinchem/hvad097.516.

VASILATOU K., WÄLCHLI C., IIDA K., HORENDER S., TRITSCHER T., HAMMER T., RISSLER J., GAIE-LEVREL F. et AUDERSET K., "Extending traceability in airborne particle size distribution measurements beyond 10 µm: Counting efficiency and unit-to-unit variability of four aerodynamic particle size spectrometers", Aerosol Science and Technology, 57, 1, 2023, 24‑34, DOI: 10.1080/02786826.2022.2139659.

WESTWOOD S., LIPPA K., SHIMUZU Y., LALERLE B., SAITO T., DUEWER D., DAI X., DAVIES S., RICCI M., BALDAN A., LANG B., SARGE S., WANG H., PRATT K., JOSEPHS R., MARIASSY M., PFEIFER D., WARREN J., BREMSER W., ELLISON S., TOMAN B., NELSON M., HUANG T., FAJGELJ A., GÖREN A., MACKAY L. et WIELGOSZ R., "Methods for the SI-traceable value assignment of the purity of organic compounds (IUPAC Technical Report)", Pure and Applied Chemistry, 95, 1, 2023, 1‑77, DOI: 10.1515/pac-2020-0804.

Communications

F. -X. OUF, F. GAIE-LEVREL, S. CHAZELET, G. FAVRE, N. FELTIN, V. FERRÉ, V. GODEFERT, J. MAST, J. NOIREAUX, S. PACAULT, X. POISSON et C. WOUTERS, "Relargage De Nano-Objets, Leurs Agrégats Et Agglomérats Depuis Les Masques : Ambitions Et Objectifs Scientifiques Du Projet RENAAME", 2023, DOI: 10.25576/ASFERA-CFA2023-33869.

DELATOUR V., "IFCC C-BM second commutability study on PTH, Joint meeting on PTH 1-84 reference materials, methods and comparisons", BIPM (Sèvres, France), 8 février 2023.

BASTARDO-FERNÁNDEZ I., CHEKRI R., NOIREAUX J., FISICARO P. et JITARU P., "Development of a novel method based on single particle icp-ms/ms and a high sensitivity sample introduction (apex) system for the characterization of titanium dioxyde nanoparticles in food simulants", European Winter Conference on Plasma Spectrochemistry, Ljubljana, Slovénie, 29 janvier-3 février 2023.

NOIREAUX J., OSTER C., HUBAU A., TOUSE S., DI LUZIO M., D’AGOSTINO G. et GHESTEM J-P., "Improving valuable metals recycling : best digestion method for retrieving Technology Critical Elements", European Winter Conference on Plasma Spectrochemistry, Ljubljana, Slovénie, 29 janvier-3 février 2023.

BASTARDO-FERNÁNDEZ I., ZAOUALI J., NOIREAUX J., CHEKRI R., FISCHER N., JITARU P. et FISICARO P., "Assessment of the measurement uncertainty related to nanoparticles characterization by sp-icp-ms using an in-house data treatment software", Congrès International de Métrologie 2023, Lyon, France, 7-10 mars 2023.

FILTZ J-R., AMALRIC L., GUIGUES N., NÄYKKI T., MARTIN V. et FISICARO P., "Metrology in the loop of the circular economy - Water Metrology - Round Table", Congrès International de Métrologie 2023, Lyon, France, 7-10 mars 2023.

FOUQUEAU A., "Towards a better monitoring of ammonia and greenhouse gases emissions from livestock production: the quantiAGREMI project", Congrès International de Métrologie 2023, Lyon, France, 7-10 mars 2023.

GUIGUES N., "EURAMET / EMN for Pollution Monitoring", Congrès International de Métrologie 2023, Lyon, France, 7-10 mars 2023.

MACÉ T., "Towards an unbroken SI-traceable calibration chain for VOCs at monitoring stations, Preparation of reference gas mixtures (RGMs) of climate relevant VOCs", Congrès International de Métrologie 2023, Lyon, France, 7-10 mars 2023.

NOIREAUX J., OSTER C., LAMAS B. et HOUDEAU E., "Accurate quantification of the bioaccumulation of titanium dioxide particles", Congrès International de Métrologie 2023, Lyon, France, 7-10 mars 2023.

DELATOUR V., "Traçabilité métrologique des résultats et contrôle de qualité congrès", congrès BIOMEDJ, Paris, France, 9 mars 2023.

ALASONATI E., GIOVANNOZZI A., CHIVAS-JOLY C., FELTIN N., FISICARO P. et ROPERS M-H., "Metrological traceability of nano and microplastic measurement data: focus on the use of the multi-detector FFF coupled offline with microscopy and Raman spectroscopy French Conference on Separative Sciences and Couplings", SEP23, Paris, France, 28-30 mars 2023.

NOIREAUX J., "Preparing electronic wastes for the chemical analysis of Technology Critical Elements", Stakeholder workshop MetroCycleEU, Virtual meeting, mars 2023.

BESCOND A., "Évaluation des performances d’instruments portables de carbone suie avec une plateforme expérimentale en environnement contrôlé", 35ème Congrès Français sur les Aérosols, Paris, France, 15-16 mars 2023.

GAIE-LEVREL F., "Métrologie des aérosols - Applications dans les domaines de la qualité de l’air, des nanotechnologies et de la santé", 35ème Congrès Français sur les Aérosols, Paris, France, 15-16 mars 2023.

MACÉ T., "Développement d’un étalon de référence pour assurer la traçabilité des mesures de NH3", Journées Techniques de l’Air, Strasbourg, France, 22-23 mars 2023.

MACÉ T., "Retour d’expérience sur les CIL LCSQA-LNE/AASQA", Journées Techniques de l’Air, Strasbourg, France, 22-23 mars 2023.

GIANGRANDE C., "Activités du LNE dans le domaine des maladies Neurodégénératives", AMI Brain-STORM, Paris, France, 29 mars 2023.

DURET C., VANEECKHOUTTE H., LALÈRE B., BONNAUD B., DELATOUR V., BOEUF A. et PICHON V., "Les hormones stéroïdiennes : contexte, enjeux et besoins métrologiques dans le sérum humain", Congrès Francophone sur les Sciences Séparatives et les Couplages 2023, Paris, France, 29-30 mars 2023.

CAPITAINE G., "L’intérêt de la métrologie pour le suivi de l’Alcalinité Totale des eaux marines", Congrès de l’école doctorale « Sciences de l’environnement – Université Aix-Marseille », 3-4 mai 2023.

BOEUF A., VANEECKHOUTTE H., HUYNH H-H., GIANGRANDE C., VELLY L., HAUSFATER P., CREAGH-BROWN B., FALINSKA AM., DEMKOW U., ANAGNOSTOPOULOU V., TSATSANIS C., CRISTOL J-P., PIERONI L., HUGGETT JF. et DELATOUR V., "Standardisation of PCT assays: Update on status, needs and feasibility", EuroMedLab, Rome, Italie, 21-25 mai 2023.

DELATOUR V., "Harmonisation of Procalcitonin as a sepsis biomarker: problems and solutions”, Session “Diagnostic Challenges in Sepsis”", EuroMedLab, Rome, Italie, 21-25 mai 2023.

GIANGRANDE C., VANEECKHOUTTE H., HIRTZ C., LEHMANN S., JEROMIN A. et DELATOUR V., "Routes to standardisation for tau protein measurement in CSF to be used in the diagnosis of neurodegenerative diseases", EuroMedLab, Rome, Italie, 21-25 mai 2023.

GUIGUES N., BONNAUD B., FISICARO P. et GUMUCHIAN D., "European Metrology Network for Pollution Monitoring POLMO", Eurachem Workshop 2023, Bern-Wabern, Suisse, 22-23 mai 2023.

GUIGUES N., "Need for the validation of on-site test kits, portable devices and continuous measuring devices for water quality monitoring", Eurachem Workshop 2023, Bern-Wabern, Suisse, 22-23 mai 2023.

GIANGRANDE C., "Mieux diagnostiquer les maladies neurodégénératives : quand la métrologie fait la différence !", Les mardis de la chimie de Sorbonne Université, Paris, France, 13 juin 2023.

GUIGUES N., "The European Metrology Network for Pollution Monitoring – PolMo.", PARC Hub FR, 16 juin 2023.

DELATOUR V., "What is commutability and why is it important?", InterQC Topics, Virtual meeting, 15 juillet 2023.

GIANGRANDE C., VANEECKHOUTTE H., HIRTZ C., LEHMANN S., JEROMIN A. et DELATOUR V., "Routes to standardisation for tau protein measurement in CSF", Alzheimer’s Association International Conference, Amsterdam, Pays-Bas, 16-20 juillet 2023.

TSE CY., ZHANG L., DAHYA K., POKUAH F., SUGAHARA O., DELATOUR V., DANILENKO U. et VESPER HW., "High Throughput ID-LCMSMS Method for Simultaneous Quantitation of Monosaccharides in Human Serum", AACC Annual Scientific Meeting & Clinical Lab Expo, Anaheim, Etats-Unis, 23-27 juillet 2023.

CAPITAINE G., "Le système des carbonates océanique : La qualité des mesures d’Alcalinité Totale et de pH pour le suivi de l’acidification des oceans", MOOSE GE 2023, août 2023.

FISICARO P., "The role of metrology into the value chain of ocean observations", IAPWS symposium, Turin, Italie, 3-8 septembre 2023.

ALASONATI E., NOIREAUX J., CHIVAS-JOLY C., FELTIN N., FISICARO P., LALÈRE B. et GIOVANNOZZI A., "Metrological characterisation of nanoparticles in FOOD products and complex matrices using AF4-MALS-ICPMS and sp-ICPMS", EMN Food “Metrological determination of micro and nano contaminants in food”, Berne, Suisse (participation à distance), 5 septembre 2023.

DELATOUR V., "Insights into the development of primary reference materials: what are the hurdles primary reference material manufacturers have to overcome?", Siemens 3rd Virtual TRSEG Assay Development Annual Conference, Virtual meeting, 28 septembre 2023.

CAPITAINE G., "Inter-laboratory comparison on a reference material for seawater spectrophotometric pHT measurements", Metrosea, Valetta Campus, Malta, octobre 2023.

GUIGUES N., "Valider les outils utilisant l’ADNe : pourquoi et comment", GT-DCE, 12 octobre 2023.

DELATOUR V., "Metrology input for post-market surveillance of IVD tests", EQALM Symposium, Lyon, France, 19 octobre 2023.

GUIGUES N., "State of the art on metrology and standardisation needs to support EU regulations.", Euramet & Welmec Metrology for regulation– Open public Consultation, Virtual meeting, 23 octobre 2023.

TSE CY., ZHANG L., DAHYA K., POKUAH F., DANILENKO U., DELATOUR V. et VESPER HW., "Comparison between ID-LC/MS/MS Serum Monosaccharides Method and Enzymatic Methods on Glucose Measurements", Diabetes Technology Meeting, Virtual meeting, 3-4 novembre 2023.

GUIGUES N., "Validation indépendante des outils innovants de mesure de la qualité de l’eau : application aux méthodes ADNe", Journées du réseau ADN-O, 29-30 novembre 2023.

BASTARDO-FERNÁNDEZ I., CHEKRI R., NOIREAUX J., FISICARO P. et JITARU P., "Development of a single particle ICP-MS method using a high efficiency sample introduction system (APEXTM) for the characterisation of titanium dioxide nanoparticles in foodstuffs", IMEKOFOOD 2023, Maisons-Alfort, France, 25-27 octobre 2023.

NOIREAUX J., "Video BIPM de présentation des activités sur la métrologie des nanoparticules au LNE à l’occasion du world Metrology Day", lien: https://www.youtube.com/watch?v=GTXMjUoLiFk&list=PL-vj-3_a7wTAKMXIKtU8jSY7bNf5TI_6s&index=10

Publications

BADRICK T., MILLER W.G., PANTEGHINI M., DELATOUR V., BERGHALL H., MACKENZIE F. and JONES G., “Interpreting EQA-Understanding Why Commutability of Materials Matters”, Clin Chem., 2022, 68, 4, 494-500, DOI: 10.1093/clinchem/hvac002.

BAUDIN B., BOEUF A., DELATOUR V., DESMONS A., GOUGET B., GRUSON D., PEOC'H K., SAPIN V., VASSAULT A., VAUBOURDOLLE M., “Reports of Euromedlab 2021, in 2022”, Ann Biol Clin, 2022, Paris, 80, 3, 274-286, DOI: 10.1684/abc.2022.1728.

BOEUF A., HUYNH H.-H., DERBEZ M., GIANGRANDE C., LALÈRE B., VASLIN-REIMANN S. and DELATOUR V., “M260 Towards the standardization of PCT assays?”, Clinica Chimica Acta, 2022, 530, Suppl.1, S431.

DELEEBEECK L., SNEDEN A. and STOICA D., “Reconciling the pHe measurements of bioethanol: pHabs measurements of buffered 50-50 wt% water-ethanol mixtures”, Anal Chim Acta X, 2022, 10, DOI: 100085. doi: 10.1016/j.acax.2022.100085.

EVARISTE L., GAULTIER E., CARTIER C., NOIREAUX J., CHASSAING B., HOUDEAU E. and LAMAS B., “P09-08 Mice exposed to food-grade titanium dioxide from in utero life to adulthood show sex-specific gut microbiota and metabolic disorders which are aggravated under Western-diet”, Toxicology Letters, 2022, 368, Suppl. S153, ISSN 0378-4274, DOI: 10.1016/j.toxlet.2022.07.429.

FOUQUEAU A., POURCHEZ J., LECLERC L., PEYRON A., MONTIGAUD Y., VERHOEVEN P., BESCOND A., MACÉ T., THOMAS D., CHARVET A., BOURROUS S., GHIJSELINGS M., HARS P., POLYN F. and GAIE-LEVREL F., “An inter-laboratory comparison between particle and bacterial filtration efficiencies of surgical masks in the COVID-19 pandemic context”, Aerosol and Air Quality Research, 2022, 23, 2, 220252, DOI: 10.4209/aaqr.220252.

GUIGUES N., CHABROL J., LAVAUD P., RAVEAU S., MAGAR J., LALÈRE B. and VASLIN REIMANN S., “Assessing the performances of on-line analyzers can greatly improve free chlorine monitoring in drinking water”, Accreditation and quality assurance, 2022, 27, 1, 43-53, 11, DOI: 10.1007/s00769-021-01488-2.

GUIGUES N., LARDY-FONTAN S., VILLENEUVE A., MANSUIT P., WELSCH S. and LALÈRE B., “Passive sampling as an alternative strategy to monitor metals and PAHs trends at an upstream and rural catchment: a French case study”, SN Applied sciences, 2022, 4, 4, 104, DOI: 10.1007/s42452-022-04990-5.

HUYNH H.-H., DELATOUR V., DERBEZ-MORIN M., LIU Q., BOEUF A. and VINH J., “Candidate High-Resolution Mass Spectrometry-Based Reference Method for the Quantification of Procalcitonin in Human Serum Using a Characterized Recombinant Protein as a Primary Calibrator”, Anal Chem., 2022, 94, 10, 4146-4154, DOI: 10.1021/acs.analchem.1c03061.

IVANOVA V., OSTER C., SURLEVA A. and FISICARO P., “Comparative evaluation of methods for quantification of mercury at trace level in aquatic biota samples as a bio-indicator”, Journal of Chemical Technology and Metallurgy, 2022, 57, 2, 328-341.

JONES G.R.D., DELATOUR V. and BADRICK T., “Metrological traceability and clinical traceability of laboratory results - the role of commutability in External Quality Assurance”, Clin Chem Lab Med., 2022, 60, 5, 669-674, DOI: 10.1515/cclm-2022-0038.

JOSEPHS R. D., LIU Q., MARTOS G., BEDU M., DAIREAUX A., CHOTEAU T., WESTWOOD S., WIELGOSZ R. I., NAMMOONNOY J., ZHANG W., YONG S., LIU H., CHEN Y., NG C. Y., LU T., WANG J., LEUNG H. W., TEO T. L., GONG X., DAI X., XIA W., FENG L., XIE J., PENG T., FANG X., WU L., LI C., SONG J., LI M., LI H., BELTRÃO P. J., NARESSI SCAPIN S. M., BACILA SADE Y., BAHADOOR A., STOCKS B. B., THIBEAULT M.-P., MELANSON J. E., GIANGRANDE C., DELATOUR V., BOEUF A., VANEECKHOUTTE H., OHLENDORF R., O'CONNOR G., HENRION A., FUNG W.-H., WONG Y.-T., SAIKUSA K., YAMASAKI T., KINUMI T., ÖZTUG M., SABAN E., AKGÖZ M., QUAGLIA M., GROVES K., CLARKSON C., DRINKWATER G. and RUPÉREZ CEBOLLA D., “Key comparison study on peptide purity-hexapeptide of HbA0”, Metrologia, 2022, 59, 08013, DOI: 10.1088/0026-1394/59/1A/08013.

JOSEPHS R. D., LIU Q., MARTOS G., BEDU M., DAIREAUX A., CHOTEAU T., WESTWOOD S., WIELGOSZ R. I., NAMMOONNOY J., ZHANG W., YONG S., LIU H., CHEN Y., NG C. Y., LU T., WANG J., LEUNG H. W., TEO T. L., ZHAI R., DAI X., CHU Z., FANG X., PENG T., XIE J., MI W., ZHU M., LIU Y., LI M., WU L., LI H., BELTRÃO P. J., NARESSI SCAPIN S. M., BACILA SADE Y., BAHADOOR A., STOCKS B. B., THIBEAULT M.-P., MELANSON J. E., GIANGRANDE C., DELATOUR V., BOEUF A., VANEECKHOUTTE H., OHLENDORF R., O'CONNOR G., HENRION A., SAIKUSA K., KINUMI T., ÖZTUG M., SABAN E., AKGÖZ M., QUAGLIA M., GROVES K., CLARKSON C., DRINKWATER G. and RUPÉREZ CEBOLLA D., “Key comparison study on peptide purity - glycated hexapeptide of HbA1c”, Metrologia, 2022, 59, 08006, DOI: 10.1088/0026-1394/59/1A/08006.

KRIEF S., IGLESIAS-GONZALEZ A., APPENZELLER B., SPIRHANZLOVA P. and LARDY-FONTAN S., “Chimpanzee exposure to pollution revealed by human biomonitoring approaches”, 2022, Ecotoxicology and Environmental Safety, 233, 113341, DOI: 10.1016/j.ecoenv.2022.113341.

MATHON B., FERREOL M., TOGOLA A., LARDY-FONTAN S., MAZELLA N. and MIEGE C., “Polar organic chemical integrative samplers as an effective tool for chemical monitoring of surface waters - Results from one-year monitoring in France”, Science of The Total Environment, 2022, 824, 153549, DOI:  10.1016/j.scitotenv.2022.153549.

MI W., JOSEPHS R.-D., MELANSON J.-E., DAI X., WANG Y., ZHAI R., CHU Z., FANG X., THIBEAULT M.-P., STOCKS B.-B., MEIJA J., BEDU M., MARTOS G., WESTWOOD S., WIELGOSZ R.-I., LIU Q., TEO T.-L., LIU H., TAN Y.-J., ÖZTUĞ M., SABAN E., KINUMI T., SAIKUSA K., SCHNEIDER R.-J., WELLER M.-G., KONTHUR Z., JAEGER C., QUAGLIA M., MUSSELL C., DRINKWATER G., GIANGRANDE C., VANEECKHOUTTE H., BOEUF A., DELATOUR V., LEE J.-E., O'CONNOR G., OHLENDORF R., HENRION A., BELTRÃO P.-J., NARESSI SCAPIN S.-M. and SADE Y.-B., “PAWG Pilot Study on Quantification of SARS-CoV-2 Monoclonal Antibody - Part 1”, Metrologia, 2022, 59, 08001, DOI: 10.1088/0026-1394/59/1A/08001.

MIRMONT E., BOEUF A., CHARMEL M., LAPREVOTE O., LARDY-FONTAN S. and LALÈRE B., “Overcoming matrix effects in quantitative liquid chromatography–mass spectrometry analysis of steroid hormones in surface waters”, Rapid Communications in Mass Spectrometry, 2022, 36, 2, e9154, DOI: 10.1002/rcm.9154.

PHILIPP R., LALERE B., GANTOIS F. and SANCHEZ C., “Supplementary comparison study - measurement capabilities for the quantification of ethanol in water”, Metrologia, Technical suppl.,  2022, 59, 1A, 08015, DOI: 10.1088/0026-1394/59/1A/08015.

ROMSHOO B., PÖHLKER M., WIEDENSOHLER A., PFEIFER S., SATURNO J., NOWAK A., CIUPEK K., QUINCEY P., VASILATOU K., ESS M. N., GINI M., ELEFTHERIADIS K., ROBINS C., GAIE-LEVREL F. and MÜLLER T., “Importance of size representation and morphology in modelling optical properties of black carbon: comparison between laboratory measurements and model simulations”, Atmospheric Measurement Techniques, 2022, 15, 6965-6989, DOI: 10.5194/amt-15-6965-2022.

VASILATOU K., WÄLCHLI C., IIDA K., HORENDER S., TRITSCHER T., HAMMER T., RISSLER J., GAIE-LEVREL F., SAKURAI H. and AUDERSET K., “Extending traceability in airborne particle size distribution measurements beyond 10 μm: Counting efficiency and unit-to-unit variability of four aerodynamic particle size spectrometers (APS 3321)”, Aerosol Science and Technology, 2022, 57, 24-34, DOI: 10.1080/02786826.2022.2139659.

WANG J.-L., ALASONATI E., FISICARO P. and BENEDETTI M.-F., “Titanium and Titanium dioxide (nano-) particles in small watersheds under different land-uses”, Journal of Hazardous Materials, 2022, 422, DOI:  126695, DOI: 10.1016/j.jhazmat.2021.126695.

Communications

DERBEZ-MORIN M., DELATOUR V., FENAILLE F., LALERE B., VASLIN-REIMANN S., BOEUF A. and BECHER F., “Development of a multiplexed LC-HRMS/MS quantification method of nine sepsis protein biomarkers in human serum”, Rencontres du Club Jeune SFSM, Pomeys, France, 7-11 mars 2022.

ALASONATI E., LARDY-FONTAN S., CHIVAS-JOLY C., FELTIN N. and FISICARO P., “LNE activities on the characterisation of the nano and microplastics in the frame of the French and European metrology strategy”, Workshop CCQM sur les microplastiques 2022, (Conférence en ligne), 5 avril 2022.

BOEUF A., HUYNH H.-H., DERBEZ M., GIANGRANDE C., VASLIN-REIMANN S., LALERE B., VINH J. and DELATOUR V., “Towards the standardization of PCT assays? Status, needs and feasibility”, EuromedLab, Munich, Allemagne, 11-15 avril 2022.

DELATOUR V., “The importance of demonstrating commutability of reference materials and EQA materials”, Congrès IFCC, Munich, Allemagne, 13 avril 2022.

BESCOND A., MACE T. and GAIE-LEVREL F., « Développement d'un aérosol atmosphérique modèle en environnement contrôlé pour la détermination des performances métrologiques de systèmes capteurs », 35ème Congrès Français sur les Aérosols, Paris, France, 9-10 mai 2022.

BASTARDO FERNÁNDEZ I., CHEKRI R., NOIREAUX J., FISICARO P.and JITARU P., “Studying analytical parameters in the characterization of TiO2 nanoparticles by Single Particle ICP MS”, SPECTRATOM 2022, Pau, France, 10-13 mai 2022.

ALASONATI E., COULIBALY C. A., DIOP N. R., BREYSSE C., LORIOT C., FELTIN N., CHIVAS-JOLY C., BENIHYA A., AINES L., RICHAUD E., THEBAULT J., FISICARO P., DOMENEK S. and SEA PLASTICS, “Methodological development for the characterization of small microplastics and nanoplastics in seawater”, SETAC Europe 32nd Annual Meeting, Copenhagen, Danemark, 15–19 mai 2022.

BESCOND A., GAIE-LEVREL F., SUTOUR C. and MACÉ T., “Development of an experimental platform for metrological performance evaluation of sensor system”, Gas Analysis 2022, Paris, France, 17-20 mai 2022.

LALÈRE B. and MARLIERE F., “Monitoring pesticides in ambient air: Method harmonization based on an analytical inter laboratory comparison (ILC)”, Gas Analysis 2022, Paris, France, 17-20 mai 2022.

MACÉ T., SUTOUR C., ITURRATE M., PASCALE C., BELLIRIDE S. and MONNET M., “Development of a reference standard to ensure the quality of the ammonia measurements performed in France”, Gas Analysis 2022, Paris, France, 17-20 mai 2022.

MACÉ T. and WETERINGS W., “Training course accreditation”, Gas Analysis 2022, Paris, France, 17-20 mai 2022.

GUIGUES N., « Évaluation des Performances de capteurs dans le domaine de l’eau, Hydréos », Club eau des industriels, 24 mai 2022.

GUIGUES N., « Évaluation des performances métrologiques de capteurs et analyseurs en ligne : exemple pour la mesuredu chlore libre en eau potable, Analyse & Environnement : air, eau, sols, co-produits », Journées Recherche et Industrie, Villeurbanne, France, 30-31 mai 2022.

ALASONATI E., “Size distribution of extracellular vesicles in biological test samples by multidetector asymmetric flow field flow fractionation (MD-AF4)”, Journée scientifique Nantes Université « Le fractionnement flux-force en santé », Nantes, France, 5 juin 2022.

DERBEZ-MORIN M., DELATOUR V., FENAILLE F., LALERE B., VASLIN-REIMANN S., HUGGETT J., BOEUF A. and BECHER F., “Multiplexed LC-HRMS/MS quantification of nine sepsis protein biomarkers in human serum”, International Mass Spectrometry Conference (IMSC) 2022, Maastricht, Pays-Bas, 27 août - 2 septembre 2022.

KOVAČIČ A., PIECHOTTA C., STEINHÄUSER L., LARDY-FONTAN S. and HEATH E., “A method for monitoring estrogens in whole surface waters by GC-MS/MS”, International Mass Spectrometry Conference (IMSC) 2022, Maastricht, Pays-Bas, 27 août - 2 septembre 2022.

LARDY-FONTAN S., PIECHOTTA C., LALERE B., LE DIOURON V., STEINHÄUSER L., HEATH E., KOVAČIČ A., POTALIVO M., DE ZORZI P., CENTIOLI D., NÄYKKI T., VIIDANOJA J., GÖKCEN T., BUDZINSKI H., LE MENACH K. and SIMON SELIH V., “A project to deliver reliable measurements of estrogens for better monitoring surveys and risk assessments”, EuChemS Chemistry Congress, Lisbonne, Portugal, 28 août – 1 septembre 2022.

PIECHOTTA C., LARDY-FONTAN S., LALERE B., LE DIOURON V., STEINHÄUSER L., HEATH E., KOVAČIČ A., POTALIVO M., DE ZORZI P., CENTIOLI D., NÄYKKI T., VIIDANOJA J., GÖKCEN T., BUDZINSKI H., LE MENACH K. and SIMON SELIH V., “A project to deliver reliable measurements of estrogens for better monitoring surveys and risk assessments”, EuChemS Chemistry Congress, Lisbonne, Portugal, 28 août – 1 septembre 2022.

ASBACH C., NOTHHELFER M., SUTTER B., WITSCHGER O., BESCOND A., GAIE-LEVREL F., RUITER S., KUIJPERS E., FRANSMAN W. and TODEA A. M., “Applicability of low cost sensors for monitoring NOAA concentrations in workplaces”, International Aerosol Conference (IAC 2022), Athènes, Grèce, 4-9 septembre 2022.

BESCOND A., KOUST HANSEN S., THU NGUYEN Q., EGHOLM BØGH PEDERSEN P., DEBERT C., MAHNAOUI A., STABILE L., GOMEZ-MORENO F.J., ERIKSSON A., RISSLER J., ELEFTHERIADIS K., VRATOLIS S. and GAIE-LEVREL F., “Performance evaluation of black carbon portable instrument with a laboratory experimental set-up under a controlled environment”, International Aerosol Conference (IAC 2022), Athènes, Grèce, 4-9 septembre 2022.

EGHOLM BØGH PEDERSEN P., THU NGUYEN Q., ERIKSSON A.C., RISSLER J., BESCOND A., GAIE-LEVREL F., STABILE L., GÓMEZ-MORENO F.J., VRATOLIS S., ELEFTHRIADIS K., WINKLER U., WIEDENSOHLER A., BUCAR K., MALET J. and KOUST HANSEN S., “Qualification of portable instruments for ambient aerosol measurements”, International Aerosol Conference (IAC 2022), Athènes, Grèce, 4-9 septembre 2022.

ERIKSSON A.C., PETERSSON SJÖGREN M., SPANNE M., KRISTENSSON A., AHLBERG E., NILSSON L., EGHOLM BØGH PEDERSEN P., THU NGUYEN Q., KOUST HANSEN S., BESCOND A., GAIE-LEVREL F., DEBERT C., MAHNAOUI A., STABILE L., GÓMEZ-MORENO F.J., VRATOLIS S., TUCH T., WINKLER U., WIEDENSOHLER A. and RISSLER J., “Field intercomparison of particle counters under winter conditions”, International Aerosol Conference (IAC 2022), Athènes, Grèce, 4-9 septembre 2022.

SPANNE M., ERIKSSON A.C., PETERSSON SJÖGREN M., ISAXON C., KRISTENSSON A., AHLBERG E., NILSSON L., SWIETLICKI E., EGHOLM BØGH PEDERSEN P., THU NGUYEN Q., KOUST HANSEN S., BESCOND A., GAIE-LEVREL F., DEBERT C., MAHNAOUI A., STABILE L., GÓMEZ-MORENO F.J., VRATOLIS S., TUCH T., WINKLER U., WIEDENSOHLER A. and RISSLER J., “Field intercomparison of stationary and portable soot instruments in a rural background environment under winter conditions”, International Aerosol Conference (IAC 2022), Athènes, Grèce, 4-9 septembre 2022.

SUTTER B., BOIVIN A., BAU S., SIMON X., WITSCHGER O., ASBACH C., TODEA A.M., BESCOND A., GAIE-LEVREL F., RUITER S., KUIJPERS E. and FRANSMAN W., “Laboratory study of the performance of low-cost aerosol sensors with regards to reference instruments when exposed to aerosolized NOAA powders”, International Aerosol Conference (IAC 2022), Athènes, Grèce, 4-9 septembre 2022.

CAPITAINE G., STOICA D., FISICARO P. and WAGENER T., “The role of quality control into the value chain of ocean carbon observations”, ICOS Science Conference, Utrecht, Pays-Bas, 15 septembre 2022.

EVARISTE L., GAULTIER E., CARTIER C., NOIREAUX J. , CHASSAING B., HOUDEAU E. and LAMAS B., « Mice exposed to food-grade titanium dioxide from in utero life to adulthood show sex-specific gut microbiota and metabolic disorders which are aggravated under Western-diet”, XVI th International Congress of Toxicology (ICT 2022), Maastrich, Pays-Bas, 18-21 septembre 2022.

DELATOUR V., « Importance de la métrologie et de la commutabilité pour l’évaluation externe de la qualité », Club utilisateurs VITROS, Conférence en ligne, 4 octobre 2022.

LARDY-FONTAN S., PIECHOTTA C., HEATH E., KOVAČIČ A., PERKOLA N., NAYKKI T., LE DIOURON V., DE ZORZI P., POTALIVO M., LE MENACH K., PARDON P., BUDZINSKI H., GOKCEN T. and LALÈRE B., “EDC-WFD: A project to deliver reliable measurements of estrogens for better monitoring survey and risks assessments of aquatic systems”, Joint IMEKO TC11 & TC24 hybrid conference 2022, Dubrovnik, Croatie, 16–19 octobre 2022.

VASLIN-REIMANN S., LARDY-FONTAN S., PETROV P., NAYKKI T., KOVAR P., MEERMANN B., JOTANOVIC A., KELLET M., EBERT V., ARNOLD D., PENNETTA H., CAN S., SCHNEIDER R., ŠOLC J., GUETTLER B., NOWAK A., MACÉ T., MAILLARD R. and FISICARO P., “How will the European Metrology Network POLMO support and improve pollution monitoring?”, Joint IMEKO TC11 & TC24 hybrid conference 2022, Dubrovnik, Croatie, 16–19 octobre 2022.

ALASONATI E., FISICARO P., LORIOT C., CHIVAS-JOLY C., ROPERS M.-H., COULIBALY C. A., BREYSSE C., BENIHYA A., DOMENEK S. and SEA PLASTICS, « Les activités LNE sur la caractérisation de nano et micro plastiques au niveau français et européen : Projets Microplast, Moustic et PlasticTrace », Comité Scientifique et Technique « ITAI ACTIA», Paris, France, 25 novembre 2022.

GUIGUES N. and VILLEMAGNE E., « Valider les outils innovants de mesure dans le domaine de l’eau : pourquoi et comment Dream », GT métrologie, 29 novembre 2022.

DELATOUR V., “How to improve the contribution of metrology institutes to medical laboratory standardization ?”, Congrès CIRME “Implementation of metrological traceability in laboratory medicine: where we are and what is missing?”, Milan, Italie, 30 novembre 2022.

Publications

ALASONATI E., CAEBERGS T., PÉTRY J., SEBAÏHI N., FISICARO P. and FELTIN N., “Size measurement of silica nanoparticles by Asymmetric Flow Field-Flow Fractionation coupled to Multi-Angle Light Scattering: a comparison exercise between two metrological institutes”, Journal of Chromatography A, 2021, 1638 (Special issue), 461859, DOI: 10.1016/j.chroma.2020.461859.

BASTKOWSKI F., SANDER B., LOZANO H., PUELLES M., SNEDDEN A., DELEEBEECK L., ASAKAI T., HWANG E., JO K., ORTIZ-APARICIO J. L., MONTERO-RUIZ J., ROZIKOVÁ M., KOZLOWSKI W., QUEZADA H. T., MORALES L. V., AHUMADA D. A., BORGES P. P., NEVES R. S., SOBRAL S. P., UYSAL E., LIV L., PROKUNIN S., DOBROVOLSKYI V., STOICA D., WU B., MA L., MÁRIÁSSY M., HANKOVÁ Z., SOBINA A., and SHIMOLIN A., “Key comparison CCQMK73.2018 Amount content of H+ in Hydrochloric acid (0.1 mol.kg-1)”, Metrologia, 2021, 58, Technical supplement, 1A, 08002, DOI: 10.1088/0026-1394/58/1A/08002.

BESCOND A., OSTER C., FISCARO P., GODDARD S., QUINCEY P., TSAKANIKA L.-A., LYMPEROPOULOU T. and OCHSENKUHN-PETROPOULOU M., “Method for preparation of a candidate reference material of PM10 and PM2.5 airborne particulate filters loaded with incineration ash-Inter comparison results for metal concentration”, Atmosphere, 2021, 12, 67, DOI: 10.3390/atmos12010067.

BETTENCOURT DA SILVA R.J.N., SAAME J., ANES B., HEERING A., LEITO I., NAYKKI T., STOICA D., DELEEBEECK L., BASTKOWSKI F., SNEDDEN A. and CAMOES M.F., “Evaluation and validation of detailed and simplified models of the uncertainty of unified pH abs H2O measurements in aqueous solutions”, Analytica Chimica Acta, 2021, 1182,1182 338923, DOI: 10.1016/j.aca.2021.338923.

BOURROUS S., BARRAULT M., MOCHO V., POIRIER S.,OUF F.-X., BARDIN-MONNIER N., CHARVET A., THOMAS D., BESCOND A., FOUQUEAU A., MACÉ T. and GAIE-LEVREL F., “A performance evaluation and inter-laboratory comparison of community face coverings in the context of COVID-19 pandemic”, Aerosol and Air Quality Research, 2021, 21, 6, DOI: 10.4209/aaqr.200615.

BUCHTA C., CAMP J.V., JOVANOVIC J., CHIBA P., PUCHHAMMER-STÖCKL E., MAYERHOFER M., PLICKA H., LERCHER A., POPA A.M., ENDLER L., BERGTHALER A., HUF W., BENKA B., DELATOUR V., MÜLLER M.M., GRIESMACHER A., ABERLE S.W. and GÖRZER I., “The versatility of external quality assessment for the surveillance of laboratory and in vitro diagnostic performance: SARS-CoV-2 viral genome detection in Austria”. Clin Chem Lab Med., 2021, 59, 10, 1735-1744, DOI: 10.1515/cclm-2021-0604.

COBBAERT C.M., ALTHAUS H., BEGCEVIC BRKOVIC I., CEGLAREK U., COASSIN S., DELATOUR V., DEPREZ L., DIKAIOS I., DITTRICH J., HOOFNAGLE A.N., KOSTNER G.M., KRONENBERG F., KUKLENYIK Z., PRINZING U., VESPER H.W., ZEGERS I. and RUHAAK L.R.,”Towards an SI-Traceable Reference Measurement System for Seven Serum Apolipoproteins Using Bottom-Up Quantitative Proteomics: Conceptual Approach Enabled by Cross-Disciplinary/Cross-Sector Collaboration”, Clin Chem., 2021, 67, 3, 478-489, DOI: 10.1093/clinchem/hvaa239.

DELEEBEECK L., SNEDDEN A., NAGY D., NAGYNÉ SZILÁGYI Z., ROZIKOVÁ M., VIČAROVÁ M., HEERING A., BASTKOWSKI F., LEITO I., QUENDERA R., CABRAL V. and STOICA D., “Unified pH measurements of ethanol, methanol, and acetonitrile, and their mixtures with water”, Sensors, 2021, 21, 3935, DOI: 10.3390/s21113935.

FIGTREE G.A., VERNON S.T., HADZIOSMANOVIC N., SUNDSTRÖM J., ALFREDSSON J., ARNOTT C., DELATOUR V., LEÓSDÓTTIR M and HAGSTRÖM E. “Mortality in STEMI patients without standard modifiable risk factors: a sex-disaggregated analysis of SWEDEHEART registry data”, Lancet, 2021, 397, 10279, 1085-1094, DOI: 10.1016/S0140-6736(21)00272-5.

HAMDAOUI Q., BENCSIK A., FLAMANT F., DELCOUR S., MACÉ T., VASLIN-REIMANN S. and GAIE-LEVREL F., “Metrological characterization of an aerosol exposure chamber to explore the inhalation effects of the combination of paraquat and TiO2 nano-objects”, Aerosol and Air Quality Research, 2021, 21, 8, DOI: 10.4209/aaqr.200626.

HAMDAOUI Q., ZEKRI Y., RICHARD S., AUBERT D., GUYOT R., MARKOSSIAN S., GAUTHIER K., GAIE-LEVREL F., BENCSIK A. and FLAMANT F., “Prenatal exposure to paraquat and nanoscaled TiO2 aerosols alters the gene expression of the developing brain”, Chemosphere, 2022, online: 16 Sept. 2021, 287, DOI: 10.1016/j.chemosphere.2021.132253.

HOOFNAGLE A.N., COBBAERT C.M., DELATOUR V., KELLEHER N.L., LOWENTHAL M.S. and SHUFORD C.M., “Should LC-MS/MS Be the Reference Measurement Procedure to Determine Protein Concentrations in Human Samples?”, Clin Chem., 2021, 67, 3, 466-471, DOI: 10.1093/clinchem/hvaa256.

HORENDER S., AUDERSET K., QUINCEY P., SEEGER S., NIELSEN SKOV S., DIRSCHERL K., SMITH T.O.M., WILLIAMS K., AEGERTER C.C., KALBERMATTER D.M., GAIE-LEVREL F. and VASILATOU K., “Facility for production of ambient-like model aerosols (PALMA) in the laboratory: application in the intercomparison of automated PM monitors with the reference gravimetric method”, Atmos. Meas. Tech., 2021, 14, 1225-1238, DOI: 10.5194/amt-14-1225-2021.

HUYNH H.H., BOEUF A., DERBEZ-MORIN M., DUPUY A.M., LALERE B., DELATOUR V. and VINH J., “Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration”, Anal Bioanal Chem., 2021, 413, 19, 4707-4725, DOI: 10.1007/s00216-021-03361-0.

HUYNH H.H., BOEUF A., DERBEZ-MORIN M., DUPUY A.M., LALERE B., VINH J. and DELATOUR V., “Response to Letter to the Editor regarding, “Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration”, Anal Bioanal Chem., 2021, 413, 19, 4921-4922, DOI: 10.1007/s00216-021-03459-5.

HUYNH H.H., BOEUF A., PFANNKUCHE J., SCHUETZ P., THELEN M., NORDIN G., VAN DER HAGEN E., KAISER P., KESSELER D., BADRICK T., POGGI B., TIIKKAINEN U., DAVIES G.J., KESSLER A., PLEBANI M., VINH J. and DELATOUR V., “Harmonization status of procalcitonin measurements: what do comparison studies and EQA schemes tell us?”, Clin Chem Lab Med., 2021, 59, 10, 1610-1622, DOI: 10.1515/cclm-2021-0566.

HUYNH H.H., BOEUF A., VINH J. and DELATOUR V., “Evaluation of the necessity and the feasibility of the standardization of procalcitonin measurements: Activities of IFCC WG-PCT with involvement of all stakeholders”, Clin Chim Acta, 2021, 515, 111-121, DOI: 10.1016/j.cca.2021.01.004.

KOLEVA B., DIMITROVA L., STOICA D. and FISICARO P., “Application of secondary pH measurement method for homogeneity and stability assessment of reference materials”, Accreditation and Quality Assurance, 2021, 26, 113–120, DOI: 10.1007/s00769-021-01464-w.

JEONG J.S., YIM Y.H., LIU Q., YONG S., LIU H., BELTRÃO B., SCAPIN S., SADE Y., GARRIDO B., BOEUF A., DELATOUR V., KILPATRICK E., LOWENTHAL M., MI W., WU L., WANG J., KINUMI T., HENRION A., OHLENDORF R., OZTUG M. and AKGOZ M., “Protein Quantification Purity-Assessed Recombinant Protein Contents in Buffer Solution using Insulin analogue - CCQMK151”, Metrologia, 2021, 58, Tech. Suppl., 08007, DOI: 10.1088/0026-1394/58/1A/08007.

LAINELA S., CAPITAINE G., HEERING A., LEITO I., AGNES B., CAMOES F. and STOICA D., “Toward Unified pH of Saline Solutions”, Water, 2021, 13, 2522, DOI: 10.3390/w13182522.

MATHON B., DABRIN A., ALLAN I., LARDY-FONTAN S., TOGOLA A., GHESTEM J-P., TIXIER C., GONZALEZ JL., ALASONATI E., FERREOL M., DHERRET L., YARI A., RICHARD L., MOREIRA A., EON M., DELEST B., POLLONO C., MUNSCHY C., NOEL-CHERY E., EL MOSSAOUI M., STAUB P-F., MAZZELLA N. and MIEGE C., « Les échantillonneurs intégratifs passifs, des outils pertinents pour améliorer la surveillance règlementaire de la qualité chimique des milieux aquatiques ? », TSM, 2021, 6, 57-71, DOI: 10.36904/tsm/202106057.

MI W., JOSEPHS R.D., MELANSON J.E., DAI X., WANG Y., ZHAI R., CHU Z., FANG X., THIBEAULT M-P., STOCKS B.B., MEIJA J., BEDU M., MARTOS G., WESTWOOD S., WIELGOSZ R.I., LIU Q., TEO T.L., LIU H., J TAN Y., ÖZTUĞ M., SABAN E., KINUMI T., SAIKUSA K., SCHNEIDER R.J., WELLER M.G., KONTHUR Z., JAEGER C., QUAGLIA M., MUSSELL C., DRINKWATER G., GIANGRANDE C., VANEECKHOUTTE H., BOEUF A., DELATOUR V., LEE J.E., O'CONNOR G., OHLENDORF R., HENRION A., BELTRÃO P.J., NARESSI SCAPIN S.M. and SADE Y.B., “PAWG Pilot Study on Quantification of SARS-CoV-2 Monoclonal Antibody - Part 1”, Metrologia, 2022, published: 13 Dec. 2021, 59,1A, DOI: 10.1088/0026-1394/59/1A/08001.

MILLER G. W., GREENBERG N., BUDD J. and DELATOUR V., “The evolving role of commutability in metrological traceability”, Clin Chim Acta., 2021, 514, 84-89, DOI: 10.1016/j.cca.2020.12.021.

MIRMONT E., BOEUF A., CHARMEL M., VASLIN-REIMANN S., LALERE B., LAPRÉVOTE O. and LARDY-FONTAN S., “Development and implementation of an analytical procedure for the quantification of natural and synthetic steroid hormones in whole surface waters”, Journal of Chromatography B, 2021, 15, 1175, DOI: 10.1016/j.jchromb.2021.122732.

NOIREAUX J., LOPEZ-SANZ S., VIDMAR J., CORREIA M., DEVOILLE L., FISICARO P. and LOESCHNERK., “Titanium dioxide nanoparticles in food: comparison of detection by triple quadrupole and high resolution ICP-MS in single particle mode”, Journal of nanoparticle research, 2021, 23, 102, DOI: 10.1007/s11051-021-05198-1.

PANTEGHINI M., BRAGA F., CAMARA J.E., DELATOUR V., VAN UYTFANGHE K., VESPER H.W., ZHANG T. and JCTLM Task Force on Reference measurement system implementation, “Optimizing available tools for achieving Result standardization: Value added by Joint Committee on Traceability in Laboratory Medicine (JCTLM)”, Clin Chem., 2021, 67, 12, DOI: 10.1093/clinchem/hvab178.

RADTKE V., STOICA D., LEITO I., CAMÕES F., KROSSING I., ANES B., ROZIKOVÁ M., DELEEBEECK L., VELTZ´E S., NÄYKKI T., BASTKOWSKI F., HEERING A., DÁNIEL N., QUENDERA R., LIV L., UYSAL E. and LAWRENCE N., “A unified pH scale for all solvents Part I - Intention and reasoning (IUPAC Technical Report)”, Pure and Applied Chemistry, 2021, 93, 9, 1049-1060, DOI: 10.1515/pac-2019-0504.

REGNIER R., AVRIN G., BARBOSA V., BOFFETY D., KALOUGUINE A. and LARDY-FONTAN S., « Validation de méthodologies d’évaluation de solutions de désherbage autonomes, dans le cadre des projets Challenge ROSE et METRICS », Revue Ouverte d'Intelligence Artificielle, 2021, 2, 1, 11-32, DOI: 10.5802/roia.8.

SEEGER S., OSAN J., OTTÓ CZÖMPÖLY O., GROSS A., STOSNACH H., STABILE L., OCHSENKUEHN-PETROPOULOU M., LAMPRINI-ARETI T., LYMPEROPOULOU T., GODDARD S., FIEBIG M., GAIE-LEVREL F., KAYSER Y. and BECKHOFF B., “Quantification of element mass concentrations in ambient aerosols by combination of cascade impactor sampling and mobile total reflection X-ray fluorescence spectroscopy”, Atmosphere, 2021, 12, 309, DOI: 10.3390/atmos12030309.

SEITZ S., ROZIKOVA M., VICAROVA M., THIRSTRUP C., WANG H. and STOICA D., “EURAMET Comparison 1462 Supplementary CCQM comparison Euramet.QM-S12 Electrolytic conductivity at pure water level - Final Report”, Metrologia, 2021, 58, Techn. suppl. 1A, 08001, DOI: 10.1088/0026-1394/58/1A/08001.

STOICA D., ANES B., FISICARO P. and FILOMENA CAMÕES M., “Feasibility of multifunction calibration of H+ responsive glass electrodes in seawater”, Pure and Applied Chemistry, 2021, 93, 12, 1487-1497, DOI: 10.1515/pac-2020-0202.

Communications

BESCOND A., GAIE-LEVREL F., SUTOUR C. and MACE T., « Protocole expérimental pour caractériser les performances des capteurs à bas coût pour la surveillance de la qualité de l'air dans un environnement contrôlé », 34e Congrès Français sur les Aérosols, Paris, France, 26-28 janvier 2021.

BOURROUS S., THOMAS D., CHARVET A., MONNIER N., FOUQUEAU A., BESCOND A., GAIE-LEVREL F. and OUF F-X., « Caracterisation des performances des masques barrière à usage non sanitaire : intercomparaison des protocoles et premiers enseignements », 34e Congrès Français sur les Aérosols, DOI: 10.25576/ASFERA-CFA2021-24841, Paris, France, 26-28 janvier 2021.

SUTTER B., BAU S., SIMON X., PAYET R., BOIVIN A., WITSCHGER O., BESCOND A. and GAIE-LEVREL F., « NOAA LCS : Un projet de recherche prénormative sur l'application des microcapteurs d'aérosols pour la mesure des NOAA sur les lieux de travail », 34e Congrès Français sur les Aérosols, Paris, France, 26-28 janvier 2021.

MATHON B., DABRIN A., ALLAN I., LARDY-FONTAN S., TOGOLA A., GHESTEM J-P., TIXIER C., GONZALEZ JL., FERREOL M., DHERRET L., YARI A., RICHARD L., MOREIRA A., EON M., DELEST B., NOEL-CHERY E., EL MOSSAOUI M., ALASONATI E., STAUB P-F., MAZZELLA N. and MIEGE C., « Présentation résultats DGT, POCIS, SR et incertitudes », Colloque restitution finale RSP, Lyon-Villeurbanne, France, mars 2021.

FOUQUEAU A., GAIE-LEVREL F., BESCOND A., VASLIN-REIMANN S. and MACE T., « Masques de protection respiratoire : du contexte normatif aux travaux de comparaison inter laboratoire pour les mesures d’efficacité de filtration », Webinaire de la Société Française des Séparations Fluides Particules, Visioconférence, 1er avril 2021.

FISICARO P., “Metrology for Ocean sciences: The European Metrology Network for Climate and Ocean Observation”, Eurogoos conference 2021, Online conference, 3-5 mai 2021.

BENCSIK A., HAMDAOUI Q., NOIREAUX J., FISICARO P., GADOT N., FLAMANT F. and GAIE-LEVREL F., “An inhalation study combining nano-TiO2 and paraquat exposure in a transgenic mouse model of parkinson's disease: a novel approach to study nanopesticides impact on brain function”, NeuroFrance 2021, Colloque virtuel international, 19-21 mai 2021.

COBBAERT C., BEGCEVIC-BRKOVIC I., DITTRICH J., KUKLENYIK Z., CEGLAREK U., ALTHAUS H., ANGLES-CANO E., COASSIN S., DELATOUR V., DEPREZ L., DIKAIOS I., HOOFNAGLE A., KOSTNER G., KRONENBERG F., PRINZING U., VESPER H. and RUHAAK R., “In transition to the next generation reference materials and reference measurement procedures for apolipoprotein standardization”, 89th European Atherosclerosis Society (EAS) Congress, Helsinki, Finlande, Proceedings: Atherosclerosis, 2021, 331, 201-e202, 10.1016/j.atherosclerosis.2021.06.618, Online Congress, 30 May – 2 June 2021.

LAINELA S., STOICA D., LEITO I., HEERING A., ANES B. and FILOMENA CAMÕES M., “How reliable is your pH data?”, ASLO, Online meeting, 22-27 juin 2021.

DELATOUR V., “Potential contribution of the EMN TraceLabMed to the HALMA project harmonization of measurands in laboratory medicine through data aggregation of EQA Data”, Online conference, 23 juin 2021.

FISICARO P., “Brief presentation of EURAMET and the research programmes in metrology”, Workshop on Standardization in extracellular vesicles metrology, Paris, France, 25 juin 2021.

STEINHÄUSER L., LARDY-FONTAN S., PIECHOTTA C., HEATH E., PERKOLA N., BALZAMO S., COTMAN M., GÖKCEN T., GARDIA-PAREGE C., BUDZINSKI H., LALERE B., “Metrology for monitoring of endocrine disrupting chemicals under the EU water framework directive”, Goldschmidt2021, Online conference, 4-9 juillet 2021.

DELATOUR V., “Reference methods and commutable reference materials for standardization of immunoassays”, IFCC-Snibe International Symposium on Immunoassay-Based Diagnostics, Online conference, 7-8 Juillet 2021.

QUAGLIA M., CANO S., FILLMER A., FLOEL A. and GIANGRANDE C., “The NeuroMET project: Metrology and innovation for early diagnosis and accurate stratification of patients with neurodegenerative diseases”, 2021 Alzheimer's Association International Conference (AAIC 2021), Proceedings: Alzheimer's & dementia, 2021, 17, S5, e053655, DOI: 10.1002/alz.053655, Denver, Colorado, USA, 26-30 July 2021.

BESCOND A., GAIE-LEVREL F. and MACÉ T., “Experimental set-up for low cost sensor system performance assessment in a controlled environment”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021

BOEUF A., MIRMONT E., CHARMEL M., LAPREVOTE O., VASLIN-REIMANN S., LALERE B. and LARDY-FONTAN S., “Towards a reliable quantification of natural steroids and analogous pharmaceuticals at ultratrace level in water and human matrix”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

DELATOUR V., « La R&D en métrologie pour assurer la fiabilité des examens de biologie médicale », 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

DERBEZ-MORIN M., DELATOUR V., FENAILLE F., LALERE B., HUGGET J., BOEUF A. and BECHER F., “Development of a LC-HRMS method for the multiplexed quantification of nine sepsis protein biomarkers in human serum”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

FOUQUEAU A., GAIE-LEVREL F., MACE T., VASLIN-REIMANN S.and BESCOND A., « Face mask filtration efficiency: a characterisation of measurement protocol and data analysis », 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

GIANGRANDE C., BOEUF A., VANEECKOUTTE H., HUYNH H.H., LALÈRE B., VASLIN-REIMANN S., VINH J., HIRTZ C., SWART C., HUGGETT J., QUAGLIA M. and DELATOUR V., “Purity analysis of primary calibrators for absolute quantitation of clinically relevant proteins: state-of-the-art and perspectives”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

LALERE B., GANTOIS F., PHILIPP R. and VASLIN-REIMANN S., “Alcoref Project: certified reference materials for breath alcohol control - An improvement in European metrological infrastructure for road safety”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

LARDY-FONTAN S., “ONE HEALTH from the initial concept to the future challenges: Metrology as a cornerstone?”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

LARDY-FONTAN S., PIECHOTTA C., HEATH E., PERKOLA N., BALZAMO S., CENTIOLI D., GARDIA-PARÈGE C., BUDZINSKI H., COTMAN M., GOKCEN T. and LALÈRE B., “EDC-WFD: a project to deliver reliable measurements of estrogens for better monitoring survey and risks assessments of aquatic systems”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

MACÉ T. and SUTOUR C., “Air pollution monitoring: Development of ammonia (NH3) reference standards at nmol/mol levels”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

MAILLARD R., “Creation of a new European Metrology Network on Pollution Monitoring (POLMO) inside EURAMET”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

MARCHAND C., SPINELLE L. and MACÉ T., “A first certification protocol for the evaluation of sensor systems dedicated to the ambient air quality monitoring”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

STOICA D., “Realization of a universal pH scale: a step forward for measuring acidity and achieve pH comparability in any media”, 20e Congrès international de métrologie (CIM 2021), Lyon, France, 7-9 sept. 2021.

DELATOUR V., “Activities of IFCC Working group on standardization of procalcitonin assays with involvement of all stakeholders”, SeptiMet Stakeholders meeting, Online conference, 14 Sept. 2021.

STOICA D., « Rôle des laboratoires nationaux de métrologie dans l’évaluation et la quantification de l’acidification des eaux marines », Atelier SOMLIT, Brest, France, 15 septembre 2021.

SEEGER S., OSAN J., CZÖMPÖLY O., GROSS A., STOSNACH H., STABILE L., OCHSENKUEHN-PETROPOULOU M., TSAKANIKA L. A., LYMPEROPOULOU T., GODDARD S., FIEBIG M., GAIE-LEVREL F., KAYSER Y. and BECKHOFF B., “Element mass concentrations in ambient aerosols, a comparison of results from filter sampling / ICP-MS and cascade impactor sampling / Mobile total reflection X-ray fluorescence spectroscopy”, 12th International Conference on “Instrumental Methods of Analysis, Online conference, 20-23 Sept. 2021.

MATHON B., DABRIN A., ALLAN I., LARDY-FONTAN S., TOGOLA A., GHESTEM J-P., TIXIER C., GONZALEZ JL., FERREOL M., DHERRET L., YARI A., RICHARD L., MOREIRA A., EON M., DELEST B., NOEL-CHERY E., EL MOSSAOUI M., ALASONATI E., STAUB P-F., MAZZELLA N. and MIEGE C., « Evaluation de la pertinence des EIP pour la surveillance réglementaire des milieux aquatiques », ASTEE, Paris, France, 28-30 septembre 2021.

FISICARO P., “Metrology for Ocean Sciences: The European Metrology Network for Climate and Ocean Observation”, MetroSea, Online conference, 4-6 octobre 2021.

STOICA D., “Implementation of documentary standards in support of international and European climate strategies”, MetroSea, Online conference, 4-6 octobre 2021.

STOICA D., FISICARO P., BASTKOWSKI F., SEITZ S. and SALVETAT F., “What place for the National Metrology Institutes in the Ocean observing system? An example for assessing and quantifying ocean acidification”, MetroSea, Online conference, 4-6 octobre 2021.

DERBEZ-MORIN M., BOEUF A., FENAILLE F., LALERE B., HUGGETT J., DELATOUR V. and BECHER F., « Développement d’une méthode LC-HRMS/MS pour la quantification multiplexée de huit biomarqueurs protéiques du sepsis dans le sérum humain », SEP 2021, Paris, France, 5-7 octobre 2021.

ALASONATI E., CAEBERGS T., PÉTRY J., SEBAÏHI N., FISICARO P. and FELTIN N., “Comparison exercise between two metrological institutes for size measurement of silica nanoparticles by Asymmetric Flow Field-Flow Fractionation coupled to Multi-Angle Light Scattering detector”, Virtual Symposium on Field- and Flow-based Separations 2021, Online conference, 11-13 octobre 2021.

ALASONATI E., « Evaluation de méthodes d’échantillonnage et de caractérisation de particules polymères disséminées dans le milieu marin », Forum Emballages LNE, Online conference, 12 octobre 2021.

FISICARO P., “Primary methods for chemical analysis and their applications at LNE”, Séminaire 60 ans CETAMA, Nîmes, France, 19-21 octobre 2021.

GUIGUES N., « Guide Eurachem - L’échantillonnage dans le processus de mesure- Apport d’exercices d’intercomparaison », Séminaire 60 ans CETAMA, Nîmes, France, 19-21 octobre 2021.

MATHON B., DABRIN A., TOGOLA A., GHESTEM J-P., ALLAN I., LARDY-FONTAN S., YARI A., FERREOL M., DHERRET L., EL MOSSAOUI M., TIXIER C., NOEL-CHERY E., MUNSCHY C., POLLONO C., ALASONATI E., GONZALEZ J-L., MAZZELLA N. and MIÈGE C., “Relevance and limitation of integrative passive samplers (IPS) in support of surface waters monitoring: results of a French national-scale study”, SETAC, Portland, USA, 14-18 novembre 2021.

DELATOUR V., “The importance of demonstrating commutability of reference materials with IQC”, EuroMedLab - Symposium Advances in IQC tools and techniques, Munich, Allemagne, 28 Nov. - 2 Dec. 2021.

FISICARO P., “Development of scientific and technical capabilities in the field of chemical analysis”, EURAMET Preparatory Workshop: 2022 Call for Research Potential Projects, Online conference, 7-9 décembre 2021.

Résumé de la thèse

Depuis une trentaine d'années, la thématique de la perturbation endocrinienne est l'objet de préoccupations politiques, réglementaires, sociétales mais également scientifiques. Cela s'explique notamment par le fait que les perturbateurs endocriniens retrouvés dans l'environnement, dont les hormones stéroïdiennes naturelles et les composés qui leur sont apparentés (composés pharmaceutiques), peuvent engendrer des effets nocifs à partir de concentrations inférieures au nanogramme par litre (ng·L-1) et représenter une menace pour la biodiversité. Du côté de la santé humaine, ces composés sont des outils largement utilisés pour le diagnostic et le suivi thérapeutique de nombreux troubles et maladies chroniques. Les travaux réalisés dans le cadre de cette thèse avaient pour objectif d'assurer, dans les deux domaines, la quantification fiable de perturbateurs endocriniens et/ou de biomarqueurs afin de permettre une prise de décision éclairée à des seuils de concentration pertinents. Une liste de 23 hormones stéroïdiennes et composés apparentés a été retenue à la suite d'une étude bibliographique mettant en évidence leur intérêt commun dans les deux domaines. Ensuite, des méthodes de quantification par LC-MS/MS ont été développées pour permettre l'analyse de ces composés d'une part dans la fraction totale des eaux continentales, et d'autre part, dans la fraction totale du sérum humain. Des limites de quantification de l'ordre de 1 ng L-1 et de 1 ng mL-1 ont respectivement été obtenues en santé environnementale et humaine. Les incertitudes de mesure ont été évaluées, apportant ainsi un degré de confiance supplémentaire aux résultats de mesure. La mise en œuvre des méthodes a notamment permis de caractériser la contamination du milieu par des composés d'intérêts dont certains peu documentés en France. Elle a également permis d'établir la traçabilité métrologique des résultats de mesure au SI. Les présents travaux constituent une importante avancée pour l'établissement de méthodes de référence multi-résidus et la future certification de matériaux de référence qui sont actuellement rares voire inexistants.

Mots clés

santé, environnement, hormone stéroïdienne, eau totale, sérum humain, niveau ultra-trace, méthode multi-résidu, spectrométrie de masse couplée à la chromatographie en phase liquide, qualité de la donnée, métrologie

Résumé de la thèse

Le dosage de la procalcitonine (PCT) permet le diagnostic précoce du sepsis et la gestion du traitement antibiotique. Comme les prises de décision médicales et la stratégie de prise en charge thérapeutique des patients reposent en général sur des valeurs seuil de concentration de PCT, il est nécessaire de disposer de résultats de mesure fiables et comparables, quelle que soit la méthode de dosage employée, dans le temps, et dans l’espace. Le thèse a porté sur la traçabilité métrologique des méthodes de mesure de la PCT. Les travaux ont consisté dans un premier temps à documenter l’état actuel de la comparabilité des mesures de la PCT par des méthodes de routine. L’analyse de l’ensemble des études de corrélation publiées et des résultats de contrôles externes de qualité a montré qu’il est difficile d’évaluer correctement la comparabilité des résultats et de comprendre l’origine de leur variabilité à partir de matériaux dont la commutabilité n’a pas été démontrée. Aussi, parait-il indispensable de mener des campagnes d’évaluation externe de qualité utilisant des matériaux de contrôle commutables. Par ailleurs, afin de répondre aux exigences réglementaires relatives au raccordement métrologique des résultats de mesure et afin de pouvoir évaluer la justesse des méthodes de routine, une méthode de référence candidate pour la quantification absolue de la PCT dans le sérum humain par dilution isotopique associée à la chromatographie en phase liquide couplée à la spectrométrie de masse a été développée et validée avec une limite de quantification de 0,25 ng/mL. Le raccordement des résultats aux unités SI a été établi par l’utilisation d’étalons primaires dont la pureté a été préalablement caractérisée par analyse des acides aminés avec correction de la contribution des impuretés identifiées par spectrométrie de masse haute résolution.

Mots clés

procalcitonine, sepsis, antibiorésistance, dilution isotopique associée à la chromatographie en phase liquide couplée à la spectrométrie de masse, méthode de référence, traçabilité métrologique

Résumé de la thèse

Parmi les nombreuses techniques existantes pour la caractérisation dimensionnelle des nanoparticules, le fractionnement par couplage flux force asymétrique (AF4) est une technique qui permet de séparer les différentes populations de nanoparticules présentes dans  un échantillon en fonction de leur diamètre hydrodynamique avant de mesurer à l’aide d’un détecteur. Ce fractionnement permet de simplifier la détection. Dans les années 1960, un modèle (appelé dans la thèse modèle classique) reliant le temps de rétention des nanoparticules au sein de l’AF4 à leur diamètre hydrodynamique a été développé, mais les hypothèses de validité du modèle ne sont pas toujours respectées dans certaines expériences. Les travaux mené pour cette thèse ont consisté, dans un premier temps, à étudier les mécanismes gouvernant la rétention au sein de l’AF4. Il a été montré que des interactions entre les nanoparticules et la paroi du canal biaisent les résultats prédits par le modèle classique. Un autre modèle (appelé dans la thèse modèle p-w) prenant en compte les interactions électrostatiques et de van der Waals a été étudié. Le modèle p-w s’est montré plus robuste que le modèle classique. Une validation de ce modèle a été conduite et un bilan d’incertitude a été développé en utilisant la méthode de Monte- Carlo. La traçabilité métrologique des résultats de mesure a également été démontrée.

Mots clés

AF4, nanoparticules, théorie FFF, validation de méthode

Texte intégral

Résumé de la thèse

L’émergence des nanopesticides (NPe), qui incorporent des nanomatériaux (NM) aux formulations des pesticides, soulève des questions quant aux effets sanitaires de ces produits susceptibles d’être inhalés après leur pulvérisation. Aucune étude n'a encore exploré les effets de l’inhalation de substances mêlant pesticides et NM, alors que certains de ces composés sont capables d’exercer des effets neurotoxiques, notamment en cas d’exposition au cours de stades critiques comme celui du neurodéveloppement. Comme les substances utilisées dans la formulation d’un NPe pourraient potentiellement provoquer des effets cocktails pour l’instant méconnus, il est ainsi nécessaire de proposer des modèles d’étude permettant l’évaluation du risque sanitaire associé à ces nouvelles technologies. Ce travail interdisciplinaire a premièrement consisté à mettre au point un dispositif d’exposition aux aérosols. S’inscrivant dans une démarche d’harmonisation des protocoles toxicologiques, cet outil répond aux exigences liées aux études par inhalation, afin de permettre une procédure d’exposition fiable, reproductible et caractérisée métrologiquement. Dans une seconde partie, ce manuscrit présente une étude réalisée chez la souris grâce au dispositif développé préalablement, mettant en jeu les aérosols de deux substances, le paraquat (PQ), un NM (le TiO2), et leur mélange modélisant un NPe. L’objectif de cette phase a été l’évaluation des effets neurotoxiques de l’exposition répétée aux aérosols d’intérêt, notamment afin d’étudier la survenue d’effets cocktails sur le cerveau. Une chambre d’exposition « corps-entier » a été mise en place et caractérisée métrologiquement. Facilement adaptable, elle peut être utilisée au sein d’études diverses impliquant plusieurs espèces de rongeurs ou scénarios d’exposition. Les différents paramètres des aérosols générés se sont avérés stables, en termes de concentrations massiques et en nombre, de distribution granulométrique et d'homogénéité de l'atmosphère, et le fonctionnement de l'installation a été évalué sur le terrain, validant ainsi son usage comme outil approprié d’évaluation toxicologique. Malgré l’usage de doses d’exposition faibles et théoriquement sans effet toxique, l’analyse par RNA-seq du transcriptome du striatum des souriceaux exposés in utero a permis d’identifier des modifications géniques pouvant refléter des altérations neurodéveloppementales, ce qui suggère que PQ et TiO2 peuvent avoir des effets néfastes sur le neurodéveloppement. Par ailleurs, l’exposition de l’animal adulte pendant plusieurs semaines a montré que le TiO2 pourrait provoquer une neurotoxicité ciblant les neurones dopaminergiques. Bien qu’aucun effet synergique n’ait été observé, les données suggèrent des phénomènes d’interaction entre ces deux composés, modulant leurs effets toxicologiques. Les résultats soulignent que la phase prénatale est primordiale dans l’évaluation du risque sanitaire associé à l’exposition aux polluants atmosphériques comme les NPe, ce qui confirme la nécessité d’avoir recours à des méthodes in vivo représentatives de scénarios d’exposition réalistes.

Mots clés

chambre d’exposition aux aérosols, toxicologie par inhalation, nanopesticide, nanomatériau, pesticide, neurodéveloppement, TiO2, paraquat, oxyde de titane, polluant atmosphérique

Texte intégral

La mesure de l'ammoniac (NH3) dans l'air ambiant est un sujet sensible et prioritaire en raison de ses effets nuisibles sur la santé humaine et sur les écosystèmes. Il a été estimé que les émissions d'ammoniac ont au moins doublé au cours du dernier siècle à travers l'Europe, ce qui s’explique essentiellement par le développement des pratiques d'élevage intensif et l'utilisation associée d'engrais à base d'azote.

OBJECTIFS

  • Développer de nouvelles approches pour la production de Matériaux de Référence Certifiés (MRC) pour l’ammoniac ainsi que de nouvelles méthodes d'analyse
  • Assurer la traçabilité des mesures réalisées par les Associations Agréées de Surveillance de la Qualité de l’Air (AASQA) sur le territoire français et pouvoir comparer les données des différentes AASQA dans le temps et dans l’espace

RÉSUMÉ ET RÉSULTATS

L'ammoniac est essentiellement émis par le secteur agricole, 96% selon les données fournies par EMEP. La France, l’Allemagne, la Belgique, l’Italie et les Pays-Bas sont les principaux pays émetteurs d’ammoniac.

Les principales sources d’ammoniac atmosphérique sont anthropiques et proviennent de la combustion de combustibles fossiles, des centrales électriques, des gaz d'échappement des véhicules et des activités agricoles.

Le dépôt d'ammoniac sur les molécules transportées par les particules contribue à l'eutrophisation et à l'acidification des sols et de l'eau douce et ainsi à une dégradation de la qualité des sols et des eaux. Ces phénomènes ont donc des effets négatifs sur la biodiversité et les écosystèmes.

La pollution atmosphérique se propage au-delà des frontières nationales et sur de longues distances. C'est pourquoi l'ammoniac a été inclus dans le protocole de Göteborg de 1999, révisé en 2012, qui fait partie de la Convention sur la pollution atmosphérique transfrontière à longue distance (Nations unies, 1979). Ce protocole a été établi dans le but de réduire l'acidification, l'eutrophisation et les concentrations d'ozone en fixant des plafonds d'émission à respecter d'ici 2010. Suite à la révision du protocole de Göteborg, la directive (UE) 2016/2284 (Commission européenne, 2016) définit des plafonds d'émission nationaux pour chaque État membre, notamment pour le NH3. L’ammoniac étant reconnu comme un précurseur des aérosols inorganiques secondaires, le contrôle de ses émissions est important pour réduire les concentrations de PM2,5 et PM10.

Ceci a conduit les réseaux de surveillance de la qualité de l’air ambiant à réaliser des mesures de concentrations de l’ammoniac sur leurs territoires. Pour atteindre l’objectif de mettre en place une infrastructure métrologique pour la qualité des mesures d'ammoniac, le LNE développe des étalons de référence de NH3 à des fractions molaires allant de 1 à 400 nmol/mol afin de couvrir la gamme des fractions molaires mesurées dans l’air ambiant et ainsi d’apporter une réponse métrologique plus adaptée au manque de traçabilité des mesures effectuées par les AASQA.

Deux pistes ont été investiguées pour le développement des étalons, l’une basée sur la fabrication de mélanges gazeux gravimétriques en bouteille à une fraction molaire de 10 μmol/mol associée à une dilution dynamique et l’autre reposant sur la perméation en phase gazeuse avec un double étage de dilution.

Au vu de la bibliographie mettant en évidence un manque de stabilité des mélanges gazeux de NH3 en bouteille, le LNE a retenu la seconde technique par perméation en phase gazeuse.

Le système de génération de NH3 par perméation gazeuse, co-développé en étroite collaboration avec la société française 2M Process est constitué :

  • D’un four permettant la régulation thermique d’un tube à perméation de NH3 à 0,01°C,
  • De plusieurs régulateurs de débit massique (RDM) permettant la dilution du mélange gazeux de NH3 généré en sortie du four de perméation,
  • D’un écran tactile en face avant permettant la commande de différentes fonctions.

Le système comporte deux étages de dilution qui permettent de générer des mélanges gazeux ayant des fractions molaires comprises entre 1 et 400 nmol/mol de NH3 en fonction des débits de dilution et du taux de perméation du tube.

Il a été montré que le système de génération de gaz étalon de NH3 par perméation gazeuse ainsi développé est fonctionnel et satisfaisant dans sa conception et son ergonomie.

IMPACTS SCIENTIFIQUES ET INDUSTRIELS

  • Mise en place d’une chaîne nationale de traçabilité métrologique entre le LNE et les AASQA sur le territoire français pour les mesures de concentration d’ammoniac afin d’assurer la traçabilité de ces mesures aux étalons de référence.
  • Amélioration de la qualité des mesures des AASQA, permettant ainsi de comparer les données des différentes AASQA dans le temps et dans l’espace. Amélioration de la modélisation et de la prévision des données de surveillance de la qualité de l’air sur le territoire français.
  • Mise à disposition de données validées d’ammoniac mesurées par les réseaux nationaux de surveillance de la qualité de l’air pour identifier des changements dus à la mise en application des politiques environnementales, pour réduire les incertitudes des inventaires d'émission actuels et pour fournir des sorties de modèles de prévision de la qualité de l’air robustes.

PARTENAIRES

Associations Agréées de Surveillance de la Qualité de l’Air (AASQA)

2M Process

Des mesures plus justes du dioxyde d'azote (NO2) sont nécessaires pour comprendre l'exposition de la population, pour améliorer les modèles de qualité de l'air et les inventaires d'émissions, pour mieux discerner les tendances à long terme des concentrations de NO2 et pour appliquer la législation sur la qualité de l'air et les émissions des véhicules.

OBJECTIFS

  • Développer des étalons de référence statiques traçables à haute fraction molaire pour le NO2 avec une incertitude cible inférieure ou égale à 0,5% et une stabilité supérieure ou égale à 2 ans
  • Développer des étalons de référence dynamiques traçables de haute précision pour les faibles fractions molaires de NO2
  • Développer des méthodes analytiques pour quantifier les principales impuretés pouvant se former lors de la préparation d'étalons de référence de NO2 statiques et dynamiques
  • Valider des méthodes spectroscopiques sélectives pour mesurer directement le NO2 et les comparer avec la méthode de référence telle que décrite dans la norme EN 14211:2012, en utilisant les résultats d’essais sur le terrain
  • S'engager avec les parties prenantes pour assurer l'adoption des étalons de référence, des méthodes d'étalonnage et des dispositifs développés dans ce projet par les organismes d'élaboration de normes, les réseaux de surveillance de la qualité de l’air, les fabricants de mélanges de gaz, les fabricants d'instruments de mesure…

RESUME ET RESULTATS

Le dioxyde d’azote (NO2) est considéré comme l’un des plus importants gaz traceurs dans l’atmosphère. Il joue un rôle clé dans la formation d’ozone et de particules secondaires, l’acidification et l’eutrophisation, et influence la capacité oxydative de l’atmosphère avec des implications pour la qualité de l’air et le changement climatique. Le NO2 est un gaz toxique ayant des répercussions directes sur la santé humaine. Le programme Global Atmosphere Watch (GAW) de l’organisation mondiale de météorologie (WMO) a identifié le NO2 comme une variable climatique essentielle qui doit être surveillée à l’échelle mondiale en raison de son importance pour la chimie atmosphérique, la qualité de l’air et le climat.

Par conséquent, l’Union européenne (UE) a fixé des valeurs limites pour les concentrations de NO2 (Directive sur la qualité de l’air - 2008/50/CE), qui sont actuellement dépassées dans 17 États membres de l’UE, ainsi que des limites supérieures pour les émissions annuelles de NOx (Directive nationale sur les plafonds d’émissions (NEC) 2001/81/CE).

En Europe, l’une des principales sources de NO2 dans les villes est la combustion de combustibles fossiles par les véhicules automobiles. Les véhicules diesel émettent vingt fois plus de NO2 que les véhicules à essence. Du fait du parc automobile, les émissions de NO2 en Europe ne diminuent pas assez rapidement, alors que la qualité de vie des citoyens européens ne pourra s’améliorer qu’avec de faibles concentrations de NO2.

En conséquence, les gouvernements de l’UE sont maintenant soumis à des pressions croissantes pour élaborer des stratégies efficaces de diminution de la pollution atmosphérique et notamment des concentrations de NO2 dans les plus brefs délais. Mais, pour définir ces stratégies, des améliorations significatives sont nécessaires au niveau de la justesse et de la comparabilité des données de mesure provenant des sites de surveillance de la qualité de l’air.

L’objectif global du projet européen intitulé MetNO2 était donc de fournir une infrastructure de mesure traçable au système international (SI) pour améliorer la qualité des mesures des concentrations de NO2 dans l’atmosphère qui répondent aux objectifs de qualité des données établis par le groupe d’experts scientifiques du programme GAW du WMO.

Afin de développer des étalons de référence statiques en bouteille avec des fractions molaires de dioxyde d'azote dans la gamme de 1 μmol/mol à 10 μmol/mol, avec une incertitude élargie de 0,5% et une stabilité supérieure à 2 ans, il est nécessaire de caractériser complètement les impuretés comprenant les principaux composés d'interférence, c'est-à-dire NOy, et spécifiquement HNO3, qui se forme par réaction de la vapeur d'eau résiduelle avec le NO2 dans la bouteille. Le LNE a développé des étalons de référence gazeux pour le NO2. Plus précisément, les travaux du LNE sur cet aspect ont porté sur la fabrication de mélanges gazeux de NO2 en bouteille à une concentration de 10 μmol/mol. L’influence du traitement/revêtement interne sur la justesse et la stabilité au cours du temps de la fraction molaire de NO2 a été testée en fabriquant des mélanges gazeux de NO2 en bouteille à une concentration de 10 μmol/mol. Les mélanges gazeux ont été fabriqués dans 2 types de bouteille de 2 fabricants différents. De même, ces mélanges gazeux ont été fabriqués dans 2 matrices différentes (air et azote) pour évaluer l’influence de la matrice sur la justesse et la stabilité au cours du temps de la fraction molaire de NO2. Le processus de fabrication a impliqué de fabriquer des mélanges gazeux intermédiaires de NO dans l’azote à des fractions molaires élevées pour pouvoir atteindre par dilution gravimétrique la fraction molaire ciblée de 10 μmol/mol. De plus, des mélanges gazeux d’oxygène ont été préparés et introduits à la dernière étape de la fabrication pour transformer le NO en NO2.

Par ailleurs, pour développer des étalons de référence dynamiques de NO2 dans la gamme de 10 nmol/mol à 500 nmol/mol avec une incertitude élargie de 1%, l'un des principaux défis a été de développer des dispositifs dynamiques capables de fournir ces étalons de référence de haute précision de NO2 pour l'étalonnage de l'instrumentation sur le terrain dans les stations de surveillance à un coût raisonnable. Ceci a impliqué le développement de méthodes analytiques pour la quantification des impuretés telles que l'eau, les espèces HNO3, NOy et N2O4 dans le gaz diluant et une étude détaillée des matériaux utilisés pour la construction du dispositif afin de minimiser l'adsorption de NO2 sur les parois, les tubes et les différents éléments du dispositif dynamique. Le LNE a finalisé les méthodes de quantification des concentrations de vapeur d’eau et de HNO3 pouvant être présents dans les mélanges gazeux dynamiques de NO2 en utilisant le générateur portable de NO2 développé par l’institut de métrologie Suisse (METAS) basé sur la méthode de perméation et un spectromètre IRFT Brüker couplé à une cellule de trajet optique de 96 m.

IMPACTS SCIENTIFIQUES ET INDUSTRIELS

  • Promouvoir l'adoption de nouveaux matériaux de référence primaires du dioxyde d'azote et partager les connaissances sur la production et l'application de ces matériaux de référence
  • Impact sur les communautés d'utilisateurs industriels par les échanges de connaissances
  • Impact sur la métrologie et les communautés scientifiques par les participations à des congrès et la publication d’articles scientifiques
  • Impact sur les normes pertinentes :
    • révision des méthodes de référence et des normes documentaires dans les commissions de normalisation internationale ISO / TC158 (Analyse des gaz) et européenne CENTC / 264 (Qualité de l'air)
    • intégration des nouvelles méthodes développées dans ce projet pour la préparation de matériaux de référence dans les prochaines révisions des normes ISO 6142 et ISO 6145 (production et certification des matériaux de référence) et ISO 19229 (analyse de pureté)
    • révision de la norme EN 14211:2012 entreprise par le CEN TC 264 / WG12
  • Améliorer la surveillance atmosphérique à long terme du NO2, soutenir l'harmonisation des données à travers l'Europe en fournissant une infrastructure de traçabilité SI, améliorer la législation pour les véhicules à moteur
  • Permettre le renforcement de la compétitivité des laboratoires nationaux de métrologie européens et des entreprises basées en Europe en améliorant les capacités européennes et en positionnant l'Europe sur les aspects métrologiques
  • Améliorer la qualité de vie des citoyens européens et réduire la charge économique des effets de l'exposition au NO2 sur la santé en facilitant l'évaluation rapide de l'efficacité des stratégies de réduction de la pollution

PARTENAIRES

NPL (Royaume-Uni)

CMI (République Tchèque)

DFM (Danemark)

IL (Finlande)

NILU (Norvège)

TUBITAK (Turquie)

VSL (Pays-Bas)

Aarhus Universitet (Danemark),

Deutscher Wetterdienst (Allemagne),

Forschungszentrum Juelich GmbH (Allemagne)

King's College London (Royaume-Uni)

University of York (Royaume-Uni)

Eidgenoessische Materialpruefungs- und Forschungsanstalt (Suisse)

Imperial College of Science, Technology and Medicine
METAS (Suisse)

PTB (Allemagne)

Le pH des solutions est probablement le concept chimique le plus largement utilisé en dehors du domaine de la chimie. La mesure et la surveillance précises des valeurs de pH sont une tâche extrêmement importante dans une grande variété de technologies et donc dans des milieux très divers. A ce jour, il est impossible de comparer les valeurs de pH de solutions réalisées dans différents solvants. Le concept théorique d'une échelle pHabs unifiée sur une base métrologique doit être développé pour être utilisable dans la pratique, grâce à des procédures de mesure et d'étalonnage.

OBJECTIFS

  • Développer et valider une procédure de mesure fiable et universellement applicable, permettant de mesurer les pHabs dans des solvants non-aqueux et mixtes, des colloïdes, etc., permettant de déterminer leurs acidités par rapport à l'échelle de pH aqueuse conventionnelle
  • Créer une méthode fiable pour l'évaluation du potentiel de jonction liquide entre les solutions aqueuses et non aqueuses où l'électrolyte de pont est un liquide ionique
  • Développer une suite cohérente et validée d'étalons pour harmoniser les systèmes de mesure de routine en termes de valeurs pHabs pour une grande variété de milieux
  • Contribuer aux spécifications internationales pour la qualité du bioéthanol EN 15490 et à d'autres organisations d'élaboration de normes pertinentes et diffuser les résultats à l'infrastructure de mesure européenne

RÉSUMÉ ET RÉSULTATS

Le pH des solutions est utilisé dans un nombre incalculable de domaines : la médecine et les sciences de la vie, la biologie, les sciences de l'environnement, l'agrologie, les sciences marines, la catalyse, les sciences des matériaux, la science de la corrosion, les sciences liées à l'énergie, etc. Il joue un rôle important dans pratiquement tous les procédés liés aux matériaux, dans leur production (ex. transformation des métaux, papiers, plastiques, verres, etc.) ainsi que dans leur retraitement (eaux usées domestiques et industrielles, extraction des déchets solides, etc.).

La variété des technologies nécessitant des mesures de pH implique une diversité de milieux dans lesquels ces processus se produisent, c'est-à-dire différents solvants, mélanges de solvants et dispersions. Pour des raisons thermodynamiques fondamentales, une comparabilité valable des valeurs de pH dans différents milieux a longtemps été impossible, même au niveau théorique. En conséquence, différentes échelles de pH existent dans différents milieux, faiblement corrélées les unes aux autres, sans possibilité de convertir une échelle dans l'autre au niveau de fiabilité nécessaire. On sait qu'il existe aujourd'hui potentiellement 1,5 million d'électrodes pH utilisées dans les applications industrielles, dont un certain nombre (10 % à 20 %) sont placées dans des mélanges de solvants qui ne sont en fait pas adaptés et conduisent à des mesures erronées.

Image
uniphied

En 2018, le LNE a coordonné le projet UnipHied (Realisation of a Unified pH Scale, lien du site ICI), financé par le programme européen EMPIR. Le concept d'acidité unifiée (pHabs) a été introduit pour surmonter cette situation, permettant la comparabilité des valeurs de pH entre toutes les phases, qu'elles soient gazeuses, liquides ou solides. Bien que conceptuellement excellent, la mise en pratique de ce concept s'est avérée extrêmement difficile et n'a pas encore été entièrement réalisée. Pour être utilisable dans la pratique, des procédures de mesure et d'étalonnage appropriées sont nécessaires.

La méthode de potentiométrie différentielle repose sur la conversion de la différence de potentiel mesurée entre deux électrodes immergées chacune dans une solution séparée par un pont salin, en différence de pH. Au cours du projet, deux méthodes de mesure de pHabsH2O ont été mises en place par les partenaires :

  • Une méthode de référence basée sur la mesure de potentiel entre deux demi-cellules d'électrodes de verre spécialisées (à contact solide) reliées par un ILSB (Ionic Liquid Salt Bridge).
  • Une méthode alternative, adaptée aux laboratoires de routine et basée sur des mesures de potentiel à l'aide d'équipements de mesure conventionnels, à savoir une demi-cellule d'électrode en verre et une électrode de référence à double jonction Ag/AgCl avec deux solutions de remplissage (solution de remplissage interne concentrée de KCl, et solution de remplissage externe liquide ionique, agissant comme un ILSB).

Les deux méthodes pHabsH2O ont été validées par des comparaisons interlaboratoires sur différents tampons pH aqueux standards ainsi que sur des milieux plus complexes tels que l'éthanol et les solvants eau-éthanol. Il a été démontré que les valeurs d'acidité unifiées (valeurs de pHabsH2O) peuvent être mesurées avec divers instruments et conceptions de cellules.

Par ailleurs, il a été découvert qu'il existe une possibilité de minimiser, voire d'éliminer le potentiel liquide-jonction (LJP) en utilisant un pont salin formé par un liquide ionique (IL) "proche de l'idéal". Bien que cet IL permette une élimination proche de l'idéal du LJP, il reste encore un certain degré d'incertitude quant à la mesure pour laquelle l'élimination est complète. Ainsi, la tâche initiale d'évaluation du LJP s'est transformée en évaluation de l'incertitude résiduelle due à une élimination éventuellement incomplète du LJP. L'IL « proche de l'idéal » étudié dans le cadre du projet permet la mise en œuvre expérimentale de l'échelle pHabsH2O pour plusieurs solvants organiques complexes. Cela contribue à obtenir des valeurs de pHabsH2O qui servent de lien thermodynamiquement bien défini entre l'acidité de l'eau et l'acidité de tout autre milieu par rapport au système aqueux. De plus, cet IL spécifique offre des avantages considérables par rapport à d'autres méthodes, à savoir sa non-toxicité.

Le développement du premier prototype de transducteur à utiliser dans le dispositif de détection pHabsH2O a montré l'efficacité de la réponse de l'élément de détection du pH dans les systèmes de solvants tamponnés/mélangés et a mis en évidence certains problèmes clés avec le système de référence et lors du déploiement de l'élément de détection du pH dans des milieux à faible salinité. Le deuxième prototype a surmonté ces problèmes en développant une cellule de référence complète et une construction d'électrodes pour minimiser les problèmes des milieux à faible conductivité. Les résultats de ce prototype montrent l'efficacité de cette approche pour surveiller le pH dans des milieux solvants mixtes avec un accord prometteur entre les valeurs de pH calculées et mesurées dans les milieux solvants aqueux et mixtes.

Des configurations ILSB pour mesurer facilement pHabsH2O avec un équipement de mesure conventionnel ont été développées dans le projet et utilisées pour démontrer l'application aux pratiques de terrain, en particulier pour la chromatographie liquide. De plus, un concept de détection a été développé en passant de l'électrode de verre traditionnelle à un système de détection à semi-conducteurs.

IMPACTS SCIENTIFIQUES ET INDUSTRIELS

  • Les résultats produits pendant la durée de vie du projet bénéficieront aux fabricants de capteurs de pH et de pH-mètres qui disposeront d'un moyen fiable pour caractériser et comparer leurs appareils dans des solutions autres qu'aqueuses
  • Les configurations ILSB développées dans le projet pour mesurer pHabsH2O peuvent être facilement adoptées pour les analyses de routine en laboratoire. À plus long terme, les laboratoires de routine pourront mesurer pHabsH2O tout en utilisant leur équipement de mesure conventionnel
  • Transfert des connaissances liées à la mesure de pHabsH2O aux prestataires de services chimiques, notamment ceux qui utilisent la chromatographie liquide et ses méthodes dérivées, les électrochimistes dans le domaine des batteries ou de la corrosion, et ceux qui travaillent dans l'industrie alimentaire
  • Le projet a encouragé la participation active aux principaux comités européens liés à la chimie tels que l'EURAMET TC MC, ainsi que le transfert de connaissances à la communauté internationale de la métrologie en chimie telle que le BIPM CCQM
  • Le projet sera un vecteur d'innovation pour le développement de la prochaine génération d'électrodes pH. De telles électrodes seraient utiles dans le domaine biomédical, notamment pour la chimiothérapie du cancer, et pourraient contribuer à la réduction du coût du traitement du cancer
  • La méthodologie développée au cours du projet pourrait être appliquée pour étudier d'autres liquides ioniques pour leur potentiel d'utilisation pour des applications d'eau de mer

PUBLICATIONS / COMMUNICATIONS

  • Agnes Heering, Daniela Stoica, Filomena Camões, Bárbara Anes, Dániel Nagy, Zsófia Nagyné Szilágyi, Raquel Quendera, Luís Ribeiro, Frank Bastkowski, Rasmus Born, Jaan Saame, Jaak Nerut, Silvie Lainela, Lokman Liv, Emrah Uysal, Matilda Roziková, Martina Vičarová, Alan Snedden, Lisa Deleebeeck, Valentin Radtke, Ingo Krossing, Ivo Leito, “Symmetric Potentiometric Cells for the measurement of Unified pH values”, Symmetry 2020, 12(7), 1150. https://doi.org/10.3390/sym12071150
  • Ricardo J.N. Bettencourt da Silva, Jaan Saame, Bárbara Anes, Agnes Heering, Ivo Leito, Teemu Näykki, Daniela Stoica, Lisa Deleebeeck, Frank Bastkowski, Alan Snedden, M. Filomena Camões, «Evaluation and validation of detailed and simplified models of the uncertainty of unified pHabsH2O measurements in aqueous solutions», 182, 2021, 338923 https://doi.org/10.1016/j.aca.2021.338923
  • Lainela, S.; Leito, I.; Heering, A.; Capitaine, G.; Anes, B.; Camões, F.; Stoica, D, «Toward Unified pH of Saline Solutions», Water 2021,13(18), 252 https://doi.org/10.3390/w13182522
  • Deleebeeck, Lisa; Snedden, Alan; Nagy, Daniel; Szilagyi Nagyne, Zsofia; Rozikova, Matilda; Vicarova, Martina; Heering, Agnes; Bastkowski, Frank; Leito, Ivo; Quendera, Raquel; Cabral, Vitor; Stoica, Daniela, «Unified pH Measurements of Ethanol, Methanol, and Acetonitrile, and Their Mixtures with Water», Sensors 2021, 21(11), 3935 https://doi.org/10.3390/s21113935

PARTENAIRES

BFKH (Hongrie)

CMI (République Tchèque)

DFM (Danemark)

IPQ (Portugal)

PTB (Allemagne)

SYKE (Finlande)

TUBITAK (Turquie)

ALU-FR (Allemagne)

ANB Sensor (Royaume-Uni)

FC.ID (Portugal)

UT (Estonie)